Loading...
TI ADC128D818 ADC System Monitor With Temperature Sensor -------------------------------------------------------- Operation modes: - Mode 0: 7 single-ended voltage readings (IN0-IN6), 1 temperature reading (internal) - Mode 1: 8 single-ended voltage readings (IN0-IN7), no temperature - Mode 2: 4 pseudo-differential voltage readings (IN0-IN1, IN3-IN2, IN4-IN5, IN7-IN6), 1 temperature reading (internal) - Mode 3: 4 single-ended voltage readings (IN0-IN3), 2 pseudo-differential voltage readings (IN4-IN5, IN7-IN6), 1 temperature reading (internal) If no operation mode is configured via device tree, the driver keeps the currently active chip operation mode (default is mode 0). Required node properties: - compatible: must be set to "ti,adc128d818" - reg: I2C address of the device Optional node properties: - ti,mode: Operation mode (u8) (see above). Example (operation mode 2): adc128d818@1d { compatible = "ti,adc128d818"; reg = <0x1d>; ti,mode = /bits/ 8 <2>; }; |