Linux Audio

Check our new training course

Embedded Linux Audio

Check our new training course
with Creative Commons CC-BY-SA
lecture materials

Bootlin logo

Elixir Cross Referencer

Loading...
.. SPDX-License-Identifier: GPL-2.0
.. include:: <isonum.txt>

===================
DPAA2 Switch driver
===================

:Copyright: |copy| 2021 NXP

The DPAA2 Switch driver probes on the Datapath Switch (DPSW) object which can
be instantiated on the following DPAA2 SoCs and their variants: LS2088A and
LX2160A.

The driver uses the switch device driver model and exposes each switch port as
a network interface, which can be included in a bridge or used as a standalone
interface. Traffic switched between ports is offloaded into the hardware.

The DPSW can have ports connected to DPNIs or to DPMACs for external access.
::

         [ethA]     [ethB]      [ethC]     [ethD]     [ethE]     [ethF]
            :          :          :          :          :          :
            :          :          :          :          :          :
       [dpaa2-eth]  [dpaa2-eth]  [              dpaa2-switch              ]
            :          :          :          :          :          :        kernel
       =============================================================================
            :          :          :          :          :          :        hardware
         [DPNI]      [DPNI]     [============= DPSW =================]
            |          |          |          |          |          |
            |           ----------           |       [DPMAC]    [DPMAC]
             -------------------------------            |          |
                                                        |          |
                                                      [PHY]      [PHY]

Creating an Ethernet Switch
===========================

The dpaa2-switch driver probes on DPSW devices found on the fsl-mc bus. These
devices can be either created statically through the boot time configuration
file - DataPath Layout (DPL) - or at runtime using the DPAA2 object APIs
(incorporated already into the restool userspace tool).

At the moment, the dpaa2-switch driver imposes the following restrictions on
the DPSW object that it will probe:

 * The minimum number of FDBs should be at least equal to the number of switch
   interfaces. This is necessary so that separation of switch ports can be
   done, ie when not under a bridge, each switch port will have its own FDB.
   ::

        fsl_dpaa2_switch dpsw.0: The number of FDBs is lower than the number of ports, cannot probe

 * Both the broadcast and flooding configuration should be per FDB. This
   enables the driver to restrict the broadcast and flooding domains of each
   FDB depending on the switch ports that are sharing it (aka are under the
   same bridge).
   ::

        fsl_dpaa2_switch dpsw.0: Flooding domain is not per FDB, cannot probe
        fsl_dpaa2_switch dpsw.0: Broadcast domain is not per FDB, cannot probe

 * The control interface of the switch should not be disabled
   (DPSW_OPT_CTRL_IF_DIS not passed as a create time option). Without the
   control interface, the driver is not capable to provide proper Rx/Tx traffic
   support on the switch port netdevices.
   ::

        fsl_dpaa2_switch dpsw.0: Control Interface is disabled, cannot probe

Besides the configuration of the actual DPSW object, the dpaa2-switch driver
will need the following DPAA2 objects:

 * 1 DPMCP - A Management Command Portal object is needed for any interraction
   with the MC firmware.

 * 1 DPBP - A Buffer Pool is used for seeding buffers intended for the Rx path
   on the control interface.

 * Access to at least one DPIO object (Software Portal) is needed for any
   enqueue/dequeue operation to be performed on the control interface queues.
   The DPIO object will be shared, no need for a private one.

Switching features
==================

The driver supports the configuration of L2 forwarding rules in hardware for
port bridging as well as standalone usage of the independent switch interfaces.

The hardware is not configurable with respect to VLAN awareness, thus any DPAA2
switch port should be used only in usecases with a VLAN aware bridge::

        $ ip link add dev br0 type bridge vlan_filtering 1

        $ ip link add dev br1 type bridge
        $ ip link set dev ethX master br1
        Error: fsl_dpaa2_switch: Cannot join a VLAN-unaware bridge

Topology and loop detection through STP is supported when ``stp_state 1`` is
used at bridge create ::

        $ ip link add dev br0 type bridge vlan_filtering 1 stp_state 1

L2 FDB manipulation (add/delete/dump) is supported.

HW FDB learning can be configured on each switch port independently through
bridge commands. When the HW learning is disabled, a fast age procedure will be
run and any previously learnt addresses will be removed.
::

        $ bridge link set dev ethX learning off
        $ bridge link set dev ethX learning on

Restricting the unknown unicast and multicast flooding domain is supported, but
not independently of each other::

        $ ip link set dev ethX type bridge_slave flood off mcast_flood off
        $ ip link set dev ethX type bridge_slave flood off mcast_flood on
        Error: fsl_dpaa2_switch: Cannot configure multicast flooding independently of unicast.

Broadcast flooding on a switch port can be disabled/enabled through the brport sysfs::

        $ echo 0 > /sys/bus/fsl-mc/devices/dpsw.Y/net/ethX/brport/broadcast_flood

Offloads
========

Routing actions (redirect, trap, drop)
--------------------------------------

The DPAA2 switch is able to offload flow-based redirection of packets making
use of ACL tables. Shared filter blocks are supported by sharing a single ACL
table between multiple ports.

The following flow keys are supported:

 * Ethernet: dst_mac/src_mac
 * IPv4: dst_ip/src_ip/ip_proto/tos
 * VLAN: vlan_id/vlan_prio/vlan_tpid/vlan_dei
 * L4: dst_port/src_port

Also, the matchall filter can be used to redirect the entire traffic received
on a port.

As per flow actions, the following are supported:

 * drop
 * mirred egress redirect
 * trap

Each ACL entry (filter) can be setup with only one of the listed
actions.

Example 1: send frames received on eth4 with a SA of 00:01:02:03:04:05 to the
CPU::

        $ tc qdisc add dev eth4 clsact
        $ tc filter add dev eth4 ingress flower src_mac 00:01:02:03:04:05 skip_sw action trap

Example 2: drop frames received on eth4 with VID 100 and PCP of 3::

        $ tc filter add dev eth4 ingress protocol 802.1q flower skip_sw vlan_id 100 vlan_prio 3 action drop

Example 3: redirect all frames received on eth4 to eth1::

        $ tc filter add dev eth4 ingress matchall action mirred egress redirect dev eth1

Example 4: Use a single shared filter block on both eth5 and eth6::

        $ tc qdisc add dev eth5 ingress_block 1 clsact
        $ tc qdisc add dev eth6 ingress_block 1 clsact
        $ tc filter add block 1 ingress flower dst_mac 00:01:02:03:04:04 skip_sw \
                action trap
        $ tc filter add block 1 ingress protocol ipv4 flower src_ip 192.168.1.1 skip_sw \
                action mirred egress redirect dev eth3

Mirroring
~~~~~~~~~

The DPAA2 switch supports only per port mirroring and per VLAN mirroring.
Adding mirroring filters in shared blocks is also supported.

When using the tc-flower classifier with the 802.1q protocol, only the
''vlan_id'' key will be accepted. Mirroring based on any other fields from the
802.1q protocol will be rejected::

        $ tc qdisc add dev eth8 ingress_block 1 clsact
        $ tc filter add block 1 ingress protocol 802.1q flower skip_sw vlan_prio 3 action mirred egress mirror dev eth6
        Error: fsl_dpaa2_switch: Only matching on VLAN ID supported.
        We have an error talking to the kernel

If a mirroring VLAN filter is requested on a port, the VLAN must to be
installed on the switch port in question either using ''bridge'' or by creating
a VLAN upper device if the switch port is used as a standalone interface::

        $ tc qdisc add dev eth8 ingress_block 1 clsact
        $ tc filter add block 1 ingress protocol 802.1q flower skip_sw vlan_id 200 action mirred egress mirror dev eth6
        Error: VLAN must be installed on the switch port.
        We have an error talking to the kernel

        $ bridge vlan add vid 200 dev eth8
        $ tc filter add block 1 ingress protocol 802.1q flower skip_sw vlan_id 200 action mirred egress mirror dev eth6

        $ ip link add link eth8 name eth8.200 type vlan id 200
        $ tc filter add block 1 ingress protocol 802.1q flower skip_sw vlan_id 200 action mirred egress mirror dev eth6

Also, it should be noted that the mirrored traffic will be subject to the same
egress restrictions as any other traffic. This means that when a mirrored
packet will reach the mirror port, if the VLAN found in the packet is not
installed on the port it will get dropped.

The DPAA2 switch supports only a single mirroring destination, thus multiple
mirror rules can be installed but their ''to'' port has to be the same::

        $ tc filter add block 1 ingress protocol 802.1q flower skip_sw vlan_id 200 action mirred egress mirror dev eth6
        $ tc filter add block 1 ingress protocol 802.1q flower skip_sw vlan_id 100 action mirred egress mirror dev eth7
        Error: fsl_dpaa2_switch: Multiple mirror ports not supported.
        We have an error talking to the kernel