Loading...
Marvell PXA camera host interface Required properties: - compatible: Should be "marvell,pxa270-qci" - reg: register base and size - interrupts: the interrupt number - any required generic properties defined in video-interfaces.txt Optional properties: - clocks: input clock (see clock-bindings.txt) - clock-output-names: should contain the name of the clock driving the sensor master clock MCLK - clock-frequency: host interface is driving MCLK, and MCLK rate is this rate Example: pxa_camera: pxa_camera@50000000 { compatible = "marvell,pxa270-qci"; reg = <0x50000000 0x1000>; interrupts = <33>; clocks = <&pxa2xx_clks 24>; clock-names = "ciclk"; clock-frequency = <50000000>; clock-output-names = "qci_mclk"; port { #address-cells = <1>; #size-cells = <0>; /* Parallel bus endpoint */ qci: endpoint@0 { reg = <0>; /* Local endpoint # */ remote-endpoint = <&mt9m111_1>; bus-width = <8>; /* Used data lines */ hsync-active = <0>; /* Active low */ vsync-active = <0>; /* Active low */ pclk-sample = <1>; /* Rising */ }; }; }; |