Loading...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 | [ { "BriefDescription": "Mispredicted indirect CALL instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc5", "EventName": "BR_MISP_RETIRED.INDIRECT_CALL", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts retired mispredicted indirect (near taken) CALL instructions, including both register and memory indirect.", "SampleAfterValue": "50021", "UMask": "0x2" }, { "BriefDescription": "Number of uops executed on the core.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xB1", "EventName": "UOPS_EXECUTED.CORE", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of uops executed from any thread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Number of uops executed on port 4 and 9", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa1", "EventName": "UOPS_DISPATCHED.PORT_4_9", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts, on the per-thread basis, cycles during which at least one uop is dispatched from the Reservation Station (RS) to ports 5 and 9.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x10" }, { "BriefDescription": "Counts the number of uops to be executed per-thread each cycle.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xb1", "EventName": "UOPS_EXECUTED.THREAD", "PEBScounters": "0,1,2,3,4,5,6,7", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Not taken branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.COND_NTAKEN", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts not taken branch instructions retired.", "SampleAfterValue": "400009", "UMask": "0x10" }, { "BriefDescription": "Uops inserted at issue-stage in order to preserve upper bits of vector registers.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x0e", "EventName": "UOPS_ISSUED.VECTOR_WIDTH_MISMATCH", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of Blend Uops issued by the Resource Allocation Table (RAT) to the reservation station (RS) in order to preserve upper bits of vector registers. Starting with the Skylake microarchitecture, these Blend uops are needed since every Intel SSE instruction executed in Dirty Upper State needs to preserve bits 128-255 of the destination register. For more information, refer to Mixing Intel AVX and Intel SSE Code section of the Optimization Guide.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Counts number of cycles no uops were dispatched to be executed on this thread.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0xB1", "EventName": "UOPS_EXECUTED.STALL_CYCLES", "Invert": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles during which no uops were dispatched from the Reservation Station (RS) per thread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "All indirect branch instructions retired (excluding RETs. TSX aborts are considered indirect branch).", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.INDIRECT", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts all indirect branch instructions retired (excluding RETs. TSX aborts is considered indirect branch).", "SampleAfterValue": "100003", "UMask": "0x80" }, { "BriefDescription": "Cycles total of 4 uops are executed on all ports and Reservation Station was not empty.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa6", "EventName": "EXE_ACTIVITY.4_PORTS_UTIL", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Cycles total of 4 uops are executed on all ports and Reservation Station (RS) was not empty.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x10" }, { "BriefDescription": "Number of uops executed on port 2 and 3", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa1", "EventName": "UOPS_DISPATCHED.PORT_2_3", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts, on the per-thread basis, cycles during which at least one uop is dispatched from the Reservation Station (RS) to ports 2 and 3.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x4" }, { "BriefDescription": "Taken branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.NEAR_TAKEN", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts taken branch instructions retired.", "SampleAfterValue": "400009", "UMask": "0x20" }, { "BriefDescription": "Counts the number of demand load dispatches that hit L1D fill buffer (FB) allocated for software prefetch.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "EventCode": "0x4c", "EventName": "LOAD_HIT_PREFETCH.SWPF", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts all not software-prefetch load dispatches that hit the fill buffer (FB) allocated for the software prefetch. It can also be incremented by some lock instructions. So it should only be used with profiling so that the locks can be excluded by ASM (Assembly File) inspection of the nearby instructions.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Number of uops executed on port 1", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa1", "EventName": "UOPS_DISPATCHED.PORT_1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts, on the per-thread basis, cycles during which at least one uop is dispatched from the Reservation Station (RS) to port 1.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Number of Uops delivered by the LSD.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "EventCode": "0xa8", "EventName": "LSD.UOPS", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts the number of uops delivered to the back-end by the LSD(Loop Stream Detector).", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Number of uops executed on port 5", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa1", "EventName": "UOPS_DISPATCHED.PORT_5", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts, on the per-thread basis, cycles during which at least one uop is dispatched from the Reservation Station (RS) to port 5.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x20" }, { "BriefDescription": "Number of uops executed on port 6", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa1", "EventName": "UOPS_DISPATCHED.PORT_6", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts, on the per-thread basis, cycles during which at least one uop is dispatched from the Reservation Station (RS) to port 6.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x40" }, { "BriefDescription": "Cycles Uops delivered by the LSD, but didn't come from the decoder.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "CounterMask": "1", "EventCode": "0xA8", "EventName": "LSD.CYCLES_ACTIVE", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts the cycles when at least one uop is delivered by the LSD (Loop-stream detector).", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Core cycles the allocator was stalled due to recovery from earlier clear event for this thread", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x0D", "EventName": "INT_MISC.RECOVERY_CYCLES", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts core cycles when the Resource allocator was stalled due to recovery from an earlier branch misprediction or machine clear event.", "SampleAfterValue": "500009", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles where the Store Buffer was full and no loads caused an execution stall.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "2", "EventCode": "0xA6", "EventName": "EXE_ACTIVITY.BOUND_ON_STORES", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles where the Store Buffer was full and no loads caused an execution stall.", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x40" }, { "BriefDescription": "Core crystal clock cycles when the thread is unhalted.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x3C", "EventName": "CPU_CLK_UNHALTED.REF_XCLK", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts core crystal clock cycles when the thread is unhalted.", "SampleAfterValue": "25003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Stalls caused by changing prefix length of the instruction.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "EventCode": "0x87", "EventName": "ILD_STALL.LCP", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts cycles that the Instruction Length decoder (ILD) stalls occurred due to dynamically changing prefix length of the decoded instruction (by operand size prefix instruction 0x66, address size prefix instruction 0x67 or REX.W for Intel64). Count is proportional to the number of prefixes in a 16B-line. This may result in a three-cycle penalty for each LCP (Length changing prefix) in a 16-byte chunk.", "SampleAfterValue": "500009", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "False dependencies in MOB due to partial compare on address.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "EventCode": "0x07", "EventName": "LD_BLOCKS_PARTIAL.ADDRESS_ALIAS", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts the number of times a load got blocked due to false dependencies in MOB due to partial compare on address.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles when Reservation Station (RS) is empty for the thread", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x5e", "EventName": "RS_EVENTS.EMPTY_CYCLES", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles during which the reservation station (RS) is empty for this logical processor. This is usually caused when the front-end pipeline runs into stravation periods (e.g. branch mispredictions or i-cache misses)", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Loads blocked due to overlapping with a preceding store that cannot be forwarded.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "EventCode": "0x03", "EventName": "LD_BLOCKS.STORE_FORWARD", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts the number of times where store forwarding was prevented for a load operation. The most common case is a load blocked due to the address of memory access (partially) overlapping with a preceding uncompleted store. Note: See the table of not supported store forwards in the Optimization Guide.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Cycles without actually retired uops.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0xc2", "EventName": "UOPS_RETIRED.STALL_CYCLES", "Invert": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "This event counts cycles without actually retired uops.", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Far branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.FAR_BRANCH", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts far branch instructions retired.", "SampleAfterValue": "100007", "UMask": "0x40" }, { "BriefDescription": "Cycles while memory subsystem has an outstanding load.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "16", "EventCode": "0xA3", "EventName": "CYCLE_ACTIVITY.CYCLES_MEM_ANY", "PEBScounters": "0,1,2,3,4,5,6,7", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x10" }, { "BriefDescription": "Number of instructions retired. Fixed Counter - architectural event", "CollectPEBSRecord": "2", "Counter": "32", "EventName": "INST_RETIRED.ANY", "PEBS": "1", "PEBScounters": "32", "PublicDescription": "Counts the number of X86 instructions retired - an Architectural PerfMon event. Counting continues during hardware interrupts, traps, and inside interrupt handlers. Notes: INST_RETIRED.ANY is counted by a designated fixed counter freeing up programmable counters to count other events. INST_RETIRED.ANY_P is counted by a programmable counter.", "SampleAfterValue": "2000003", "UMask": "0x1" }, { "BriefDescription": "Counts cycles where the pipeline is stalled due to serializing operations.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa2", "EventName": "RESOURCE_STALLS.SCOREBOARD", "PEBScounters": "0,1,2,3,4,5,6,7", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Increments whenever there is an update to the LBR array.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xcc", "EventName": "MISC_RETIRED.LBR_INSERTS", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Increments when an entry is added to the Last Branch Record (LBR) array (or removed from the array in case of RETURNs in call stack mode). The event requires LBR enable via IA32_DEBUGCTL MSR and branch type selection via MSR_LBR_SELECT.", "SampleAfterValue": "100003", "UMask": "0x20" }, { "BriefDescription": "Number of instructions retired. General Counter - architectural event", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc0", "EventName": "INST_RETIRED.ANY_P", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of X86 instructions retired - an Architectural PerfMon event. Counting continues during hardware interrupts, traps, and inside interrupt handlers. Notes: INST_RETIRED.ANY is counted by a designated fixed counter freeing up programmable counters to count other events. INST_RETIRED.ANY_P is counted by a programmable counter.", "SampleAfterValue": "2000003" }, { "BriefDescription": "Counts the number of x87 uops dispatched.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xB1", "EventName": "UOPS_EXECUTED.X87", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of x87 uops executed.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x10" }, { "BriefDescription": "Cycles at least 2 micro-op is executed from any thread on physical core.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "2", "EventCode": "0xB1", "EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_2", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles when at least 2 micro-ops are executed from any thread on physical core.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Cycles stalled due to no store buffers available. (not including draining form sync).", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa2", "EventName": "RESOURCE_STALLS.SB", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts allocation stall cycles caused by the store buffer (SB) being full. This counts cycles that the pipeline back-end blocked uop delivery from the front-end.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x8" }, { "BriefDescription": "The number of times that split load operations are temporarily blocked because all resources for handling the split accesses are in use.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "EventCode": "0x03", "EventName": "LD_BLOCKS.NO_SR", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts the number of times that split load operations are temporarily blocked because all resources for handling the split accesses are in use.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x8" }, { "BriefDescription": "Number of machine clears (nukes) of any type.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EdgeDetect": "1", "EventCode": "0xc3", "EventName": "MACHINE_CLEARS.COUNT", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of machine clears (nukes) of any type.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Number of near branch instructions retired that were mispredicted and taken.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc5", "EventName": "BR_MISP_RETIRED.NEAR_TAKEN", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts number of near branch instructions retired that were mispredicted and taken.", "SampleAfterValue": "50021", "UMask": "0x20" }, { "BriefDescription": "Return instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.NEAR_RETURN", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts return instructions retired.", "SampleAfterValue": "100007", "UMask": "0x8" }, { "BriefDescription": "Cycles when divide unit is busy executing divide or square root operations.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0x14", "EventName": "ARITH.DIVIDER_ACTIVE", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles when divide unit is busy executing divide or square root operations. Accounts for integer and floating-point operations.", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x9" }, { "BriefDescription": "Cycles total of 1 uop is executed on all ports and Reservation Station was not empty.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa6", "EventName": "EXE_ACTIVITY.1_PORTS_UTIL", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles during which a total of 1 uop was executed on all ports and Reservation Station (RS) was not empty.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Cycles without actually retired instructions.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0xc0", "EventName": "INST_RETIRED.STALL_CYCLES", "Invert": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "This event counts cycles without actually retired instructions.", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Mispredicted non-taken conditional branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc5", "EventName": "BR_MISP_RETIRED.COND_NTAKEN", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of conditional branch instructions retired that were mispredicted and the branch direction was not taken.", "SampleAfterValue": "50021", "UMask": "0x10" }, { "BriefDescription": "Core cycles when the thread is not in halt state", "CollectPEBSRecord": "2", "Counter": "33", "EventName": "CPU_CLK_UNHALTED.THREAD", "PEBScounters": "33", "PublicDescription": "Counts the number of core cycles while the thread is not in a halt state. The thread enters the halt state when it is running the HLT instruction. This event is a component in many key event ratios. The core frequency may change from time to time due to transitions associated with Enhanced Intel SpeedStep Technology or TM2. For this reason this event may have a changing ratio with regards to time. When the core frequency is constant, this event can approximate elapsed time while the core was not in the halt state. It is counted on a dedicated fixed counter, leaving the eight programmable counters available for other events.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Taken conditional branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.COND_TAKEN", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts taken conditional branch instructions retired.", "SampleAfterValue": "400009", "UMask": "0x1" }, { "BriefDescription": "Direct and indirect near call instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.NEAR_CALL", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts both direct and indirect near call instructions retired.", "SampleAfterValue": "100007", "UMask": "0x2" }, { "BriefDescription": "Cycles at least 4 micro-op is executed from any thread on physical core.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "4", "EventCode": "0xB1", "EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_4", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles when at least 4 micro-ops are executed from any thread on physical core.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Precise instruction retired event with a reduced effect of PEBS shadow in IP distribution", "CollectPEBSRecord": "2", "Counter": "32", "EventName": "INST_RETIRED.PREC_DIST", "PEBS": "1", "PEBScounters": "32", "PublicDescription": "A version of INST_RETIRED that allows for a more unbiased distribution of samples across instructions retired. It utilizes the Precise Distribution of Instructions Retired (PDIR) feature to mitigate some bias in how retired instructions get sampled. Use on Fixed Counter 0.", "SampleAfterValue": "2000003", "UMask": "0x1" }, { "BriefDescription": "Total execution stalls.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "4", "EventCode": "0xa3", "EventName": "CYCLE_ACTIVITY.STALLS_TOTAL", "PEBScounters": "0,1,2,3,4,5,6,7", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x4" }, { "BriefDescription": "Execution stalls while L1 cache miss demand load is outstanding.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "CounterMask": "12", "EventCode": "0xA3", "EventName": "CYCLE_ACTIVITY.STALLS_L1D_MISS", "PEBScounters": "0,1,2,3", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0xc" }, { "BriefDescription": "Number of retired PAUSE instructions. This event is not supported on first SKL and KBL products.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xcc", "EventName": "MISC_RETIRED.PAUSE_INST", "PublicDescription": "Counts number of retired PAUSE instructions. This event is not supported on first SKL and KBL products.", "SampleAfterValue": "100003", "UMask": "0x40" }, { "BriefDescription": "Self-modifying code (SMC) detected.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc3", "EventName": "MACHINE_CLEARS.SMC", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts self-modifying code (SMC) detected, which causes a machine clear.", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x4" }, { "BriefDescription": "Uops that RAT issues to RS", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x0e", "EventName": "UOPS_ISSUED.ANY", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of uops that the Resource Allocation Table (RAT) issues to the Reservation Station (RS).", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Execution stalls while L2 cache miss demand load is outstanding.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "CounterMask": "5", "EventCode": "0xa3", "EventName": "CYCLE_ACTIVITY.STALLS_L2_MISS", "PEBScounters": "0,1,2,3", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x5" }, { "BriefDescription": "Reference cycles when the core is not in halt state.", "CollectPEBSRecord": "2", "Counter": "34", "EventName": "CPU_CLK_UNHALTED.REF_TSC", "PEBScounters": "34", "PublicDescription": "Counts the number of reference cycles when the core is not in a halt state. The core enters the halt state when it is running the HLT instruction or the MWAIT instruction. This event is not affected by core frequency changes (for example, P states, TM2 transitions) but has the same incrementing frequency as the time stamp counter. This event can approximate elapsed time while the core was not in a halt state. This event has a constant ratio with the CPU_CLK_UNHALTED.REF_XCLK event. It is counted on a dedicated fixed counter, leaving the eight programmable counters available for other events. Note: On all current platforms this event stops counting during 'throttling (TM)' states duty off periods the processor is 'halted'. The counter update is done at a lower clock rate then the core clock the overflow status bit for this counter may appear 'sticky'. After the counter has overflowed and software clears the overflow status bit and resets the counter to less than MAX. The reset value to the counter is not clocked immediately so the overflow status bit will flip 'high (1)' and generate another PMI (if enabled) after which the reset value gets clocked into the counter. Therefore, software will get the interrupt, read the overflow status bit '1 for bit 34 while the counter value is less than MAX. Software should ignore this case.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x3" }, { "BriefDescription": "Cycles the Backend cluster is recovering after a miss-speculation or a Store Buffer or Load Buffer drain stall.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0x0D", "EventName": "INT_MISC.ALL_RECOVERY_CYCLES", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles the Backend cluster is recovering after a miss-speculation or a Store Buffer or Load Buffer drain stall.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x3" }, { "BriefDescription": "Cycles total of 2 uops are executed on all ports and Reservation Station was not empty.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa6", "EventName": "EXE_ACTIVITY.2_PORTS_UTIL", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles during which a total of 2 uops were executed on all ports and Reservation Station (RS) was not empty.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x4" }, { "BriefDescription": "Cycles total of 3 uops are executed on all ports and Reservation Station was not empty.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa6", "EventName": "EXE_ACTIVITY.3_PORTS_UTIL", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Cycles total of 3 uops are executed on all ports and Reservation Station (RS) was not empty.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x8" }, { "BriefDescription": "Cycles while L1 cache miss demand load is outstanding.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "CounterMask": "8", "EventCode": "0xA3", "EventName": "CYCLE_ACTIVITY.CYCLES_L1D_MISS", "PEBScounters": "0,1,2,3", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x8" }, { "BriefDescription": "Counts cycles after recovery from a branch misprediction or machine clear till the first uop is issued from the resteered path.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x0d", "EventName": "INT_MISC.CLEAR_RESTEER_CYCLES", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Cycles after recovery from a branch misprediction or machine clear till the first uop is issued from the resteered path.", "SampleAfterValue": "500009", "Speculative": "1", "UMask": "0x80" }, { "BriefDescription": "Cycles with less than 10 actually retired uops.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "10", "EventCode": "0xc2", "EventName": "UOPS_RETIRED.TOTAL_CYCLES", "Invert": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the number of cycles using always true condition (uops_ret < 16) applied to non PEBS uops retired event.", "SampleAfterValue": "1000003", "UMask": "0x2" }, { "BriefDescription": "All branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.ALL_BRANCHES", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts all branch instructions retired.", "SampleAfterValue": "400009" }, { "BriefDescription": "Counts end of periods where the Reservation Station (RS) was empty.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EdgeDetect": "1", "EventCode": "0x5E", "EventName": "RS_EVENTS.EMPTY_END", "Invert": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts end of periods where the Reservation Station (RS) was empty. Could be useful to closely sample on front-end latency issues (see the FRONTEND_RETIRED event of designated precise events)", "SampleAfterValue": "100003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycle counts are evenly distributed between active threads in the Core.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xec", "EventName": "CPU_CLK_UNHALTED.DISTRIBUTED", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "This event distributes cycle counts between active hyperthreads, i.e., those in C0. A hyperthread becomes inactive when it executes the HLT or MWAIT instructions. If all other hyperthreads are inactive (or disabled or do not exist), all counts are attributed to this hyperthread. To obtain the full count when the Core is active, sum the counts from each hyperthread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Core crystal clock cycles when this thread is unhalted and the other thread is halted.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x3C", "EventName": "CPU_CLK_UNHALTED.ONE_THREAD_ACTIVE", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts Core crystal clock cycles when current thread is unhalted and the other thread is halted.", "SampleAfterValue": "25003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Thread cycles when thread is not in halt state", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x3C", "EventName": "CPU_CLK_UNHALTED.THREAD_P", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "This is an architectural event that counts the number of thread cycles while the thread is not in a halt state. The thread enters the halt state when it is running the HLT instruction. The core frequency may change from time to time due to power or thermal throttling. For this reason, this event may have a changing ratio with regards to wall clock time.", "SampleAfterValue": "2000003", "Speculative": "1" }, { "BriefDescription": "Mispredicted conditional branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc5", "EventName": "BR_MISP_RETIRED.COND", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts mispredicted conditional branch instructions retired.", "SampleAfterValue": "50021", "UMask": "0x11" }, { "BriefDescription": "Number of uops executed on port 0", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa1", "EventName": "UOPS_DISPATCHED.PORT_0", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts, on the per-thread basis, cycles during which at least one uop is dispatched from the Reservation Station (RS) to port 0.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Conditional branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc4", "EventName": "BR_INST_RETIRED.COND", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts conditional branch instructions retired.", "SampleAfterValue": "400009", "UMask": "0x11" }, { "BriefDescription": "Retirement slots used.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc2", "EventName": "UOPS_RETIRED.SLOTS", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts the retirement slots used each cycle.", "SampleAfterValue": "2000003", "UMask": "0x2" }, { "BriefDescription": "Cycles optimal number of Uops delivered by the LSD, but did not come from the decoder.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "CounterMask": "5", "EventCode": "0xa8", "EventName": "LSD.CYCLES_OK", "PEBScounters": "0,1,2,3", "PublicDescription": "Counts the cycles when optimal number of uops is delivered by the LSD (Loop-stream detector).", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Core crystal clock cycles. Cycle counts are evenly distributed between active threads in the Core.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x3c", "EventName": "CPU_CLK_UNHALTED.REF_DISTRIBUTED", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "This event distributes Core crystal clock cycle counts between active hyperthreads, i.e., those in C0 sleep-state. A hyperthread becomes inactive when it executes the HLT or MWAIT instructions. If one thread is active in a core, all counts are attributed to this hyperthread. To obtain the full count when the Core is active, sum the counts from each hyperthread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x8" }, { "BriefDescription": "Cycles where at least 3 uops were executed per-thread", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "3", "EventCode": "0xb1", "EventName": "UOPS_EXECUTED.CYCLES_GE_3", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Cycles where at least 3 uops were executed per-thread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles where at least 2 uops were executed per-thread", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "2", "EventCode": "0xb1", "EventName": "UOPS_EXECUTED.CYCLES_GE_2", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Cycles where at least 2 uops were executed per-thread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles where at least 1 uop was executed per-thread", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0xb1", "EventName": "UOPS_EXECUTED.CYCLES_GE_1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Cycles where at least 1 uop was executed per-thread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles where at least 4 uops were executed per-thread", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "4", "EventCode": "0xb1", "EventName": "UOPS_EXECUTED.CYCLES_GE_4", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Cycles where at least 4 uops were executed per-thread.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles while L2 cache miss demand load is outstanding.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3", "CounterMask": "1", "EventCode": "0xA3", "EventName": "CYCLE_ACTIVITY.CYCLES_L2_MISS", "PEBScounters": "0,1,2,3", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles when RAT does not issue Uops to RS for the thread", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0x0E", "EventName": "UOPS_ISSUED.STALL_CYCLES", "Invert": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles during which the Resource Allocation Table (RAT) does not issue any Uops to the reservation station (RS) for the current thread.", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x1" }, { "BriefDescription": "Cycles at least 3 micro-op is executed from any thread on physical core.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "3", "EventCode": "0xB1", "EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_3", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles when at least 3 micro-ops are executed from any thread on physical core.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "Cycles at least 1 micro-op is executed from any thread on physical core.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "1", "EventCode": "0xB1", "EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts cycles when at least 1 micro-op is executed from any thread on physical core.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x2" }, { "BriefDescription": "All miss-predicted indirect branch instructions retired (excluding RETs. TSX aborts is considered indirect branch).", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc5", "EventName": "BR_MISP_RETIRED.INDIRECT", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts all miss-predicted indirect branch instructions retired (excluding RETs. TSX aborts is considered indirect branch).", "SampleAfterValue": "50021", "UMask": "0x80" }, { "BriefDescription": "TMA slots where uops got dropped", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0x0d", "EventName": "INT_MISC.UOP_DROPPING", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Estimated number of Top-down Microarchitecture Analysis slots that got dropped due to non front-end reasons", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x10" }, { "BriefDescription": "Execution stalls while memory subsystem has an outstanding load.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "CounterMask": "20", "EventCode": "0xa3", "EventName": "CYCLE_ACTIVITY.STALLS_MEM_ANY", "PEBScounters": "0,1,2,3,4,5,6,7", "SampleAfterValue": "1000003", "Speculative": "1", "UMask": "0x14" }, { "BriefDescription": "Number of uops executed on port 7 and 8", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xa1", "EventName": "UOPS_DISPATCHED.PORT_7_8", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts, on the per-thread basis, cycles during which at least one uop is dispatched from the Reservation Station (RS) to ports 7 and 8.", "SampleAfterValue": "2000003", "Speculative": "1", "UMask": "0x80" }, { "BriefDescription": "number of branch instructions retired that were mispredicted and taken. Non PEBS", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc5", "EventName": "BR_MISP_RETIRED.COND_TAKEN", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts taken conditional mispredicted branch instructions retired.", "SampleAfterValue": "50021", "UMask": "0x1" }, { "BriefDescription": "All mispredicted branch instructions retired.", "CollectPEBSRecord": "2", "Counter": "0,1,2,3,4,5,6,7", "EventCode": "0xc5", "EventName": "BR_MISP_RETIRED.ALL_BRANCHES", "PEBS": "1", "PEBScounters": "0,1,2,3,4,5,6,7", "PublicDescription": "Counts all the retired branch instructions that were mispredicted by the processor. A branch misprediction occurs when the processor incorrectly predicts the destination of the branch. When the misprediction is discovered at execution, all the instructions executed in the wrong (speculative) path must be discarded, and the processor must start fetching from the correct path.", "SampleAfterValue": "50021" } ] |