Loading...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 | .. SPDX-License-Identifier: GFDL-1.1-no-invariants-or-later .. _lirc_dev_intro: ************ Introduction ************ LIRC stands for Linux Infrared Remote Control. The LIRC device interface is a bi-directional interface for transporting raw IR and decoded scancodes data between userspace and kernelspace. Fundamentally, it is just a chardev (/dev/lircX, for X = 0, 1, 2, ...), with a number of standard struct file_operations defined on it. With respect to transporting raw IR and decoded scancodes to and fro, the essential fops are read, write and ioctl. It is also possible to attach a BPF program to a LIRC device for decoding raw IR into scancodes. Example dmesg output upon a driver registering w/LIRC: .. code-block:: none $ dmesg |grep lirc_dev rc rc0: lirc_dev: driver mceusb registered at minor = 0, raw IR receiver, raw IR transmitter What you should see for a chardev: .. code-block:: none $ ls -l /dev/lirc* crw-rw---- 1 root root 248, 0 Jul 2 22:20 /dev/lirc0 Note that the package `v4l-utils <https://git.linuxtv.org/v4l-utils.git/>`_ contains tools for working with LIRC devices: - ir-ctl: can receive raw IR and transmit IR, as well as query LIRC device features. - ir-keytable: can load keymaps; allows you to set IR kernel protocols; load BPF IR decoders and test IR decoding. Some BPF IR decoders are also provided. .. _lirc_modes: ********** LIRC modes ********** LIRC supports some modes of receiving and sending IR codes, as shown on the following table. .. _lirc-mode-scancode: .. _lirc-scancode-flag-toggle: .. _lirc-scancode-flag-repeat: ``LIRC_MODE_SCANCODE`` This mode is for both sending and receiving IR. For transmitting (aka sending), create a ``struct lirc_scancode`` with the desired scancode set in the ``scancode`` member, :c:type:`rc_proto` set to the :ref:`IR protocol <Remote_controllers_Protocols>`, and all other members set to 0. Write this struct to the lirc device. For receiving, you read ``struct lirc_scancode`` from the LIRC device. The ``scancode`` field is set to the received scancode and the :ref:`IR protocol <Remote_controllers_Protocols>` is set in :c:type:`rc_proto`. If the scancode maps to a valid key code, this is set in the ``keycode`` field, else it is set to ``KEY_RESERVED``. The ``flags`` can have ``LIRC_SCANCODE_FLAG_TOGGLE`` set if the toggle bit is set in protocols that support it (e.g. rc-5 and rc-6), or ``LIRC_SCANCODE_FLAG_REPEAT`` for when a repeat is received for protocols that support it (e.g. nec). In the Sanyo and NEC protocol, if you hold a button on remote, rather than repeating the entire scancode, the remote sends a shorter message with no scancode, which just means button is held, a "repeat". When this is received, the ``LIRC_SCANCODE_FLAG_REPEAT`` is set and the scancode and keycode is repeated. With nec, there is no way to distinguish "button hold" from "repeatedly pressing the same button". The rc-5 and rc-6 protocols have a toggle bit. When a button is released and pressed again, the toggle bit is inverted. If the toggle bit is set, the ``LIRC_SCANCODE_FLAG_TOGGLE`` is set. The ``timestamp`` field is filled with the time nanoseconds (in ``CLOCK_MONOTONIC``) when the scancode was decoded. .. _lirc-mode-mode2: ``LIRC_MODE_MODE2`` The driver returns a sequence of pulse and space codes to userspace, as a series of u32 values. This mode is used only for IR receive. The upper 8 bits determine the packet type, and the lower 24 bits the payload. Use ``LIRC_VALUE()`` macro to get the payload, and the macro ``LIRC_MODE2()`` will give you the type, which is one of: ``LIRC_MODE2_PULSE`` Signifies the presence of IR in microseconds. ``LIRC_MODE2_SPACE`` Signifies absence of IR in microseconds. ``LIRC_MODE2_FREQUENCY`` If measurement of the carrier frequency was enabled with :ref:`lirc_set_measure_carrier_mode` then this packet gives you the carrier frequency in Hertz. ``LIRC_MODE2_TIMEOUT`` If timeout reports are enabled with :ref:`lirc_set_rec_timeout_reports`, when the timeout set with :ref:`lirc_set_rec_timeout` expires due to no IR being detected, this packet will be sent, with the number of microseconds with no IR. .. _lirc-mode-pulse: ``LIRC_MODE_PULSE`` In pulse mode, a sequence of pulse/space integer values are written to the lirc device using :ref:`lirc-write`. The values are alternating pulse and space lengths, in microseconds. The first and last entry must be a pulse, so there must be an odd number of entries. This mode is used only for IR send. ******************** BPF based IR decoder ******************** The kernel has support for decoding the most common :ref:`IR protocols <Remote_controllers_Protocols>`, but there are many protocols which are not supported. To support these, it is possible to load an BPF program which does the decoding. This can only be done on LIRC devices which support reading raw IR. First, using the `bpf(2)`_ syscall with the ``BPF_LOAD_PROG`` argument, program must be loaded of type ``BPF_PROG_TYPE_LIRC_MODE2``. Once attached to the LIRC device, this program will be called for each pulse, space or timeout event on the LIRC device. The context for the BPF program is a pointer to a unsigned int, which is a :ref:`LIRC_MODE_MODE2 <lirc-mode-mode2>` value. When the program has decoded the scancode, it can be submitted using the BPF functions ``bpf_rc_keydown()`` or ``bpf_rc_repeat()``. Mouse or pointer movements can be reported using ``bpf_rc_pointer_rel()``. Once you have the file descriptor for the ``BPF_PROG_TYPE_LIRC_MODE2`` BPF program, it can be attached to the LIRC device using the `bpf(2)`_ syscall. The target must be the file descriptor for the LIRC device, and the attach type must be ``BPF_LIRC_MODE2``. No more than 64 BPF programs can be attached to a single LIRC device at a time. .. _bpf(2): http://man7.org/linux/man-pages/man2/bpf.2.html |