Loading...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 | Mylex DAC960/DAC1100 PCI RAID Controller Driver for Linux Version 2.2.5 for Linux 2.2.14 Version 2.0.5 for Linux 2.0.38 PRODUCTION RELEASE 23 January 2000 Leonard N. Zubkoff Dandelion Digital lnz@dandelion.com Copyright 1998-2000 by Leonard N. Zubkoff <lnz@dandelion.com> INTRODUCTION Mylex, Inc. designs and manufactures a variety of high performance PCI RAID controllers. Mylex Corporation is located at 34551 Ardenwood Blvd., Fremont, California 94555, USA and can be reached at 510/796-6100 or on the World Wide Web at http://www.mylex.com. Mylex RAID Technical Support can be reached by electronic mail at support@mylex.com (for eXtremeRAID 1100 and older DAC960 models) or techsup@mylex.com (for AcceleRAID models), by voice at 510/608-2400, or by FAX at 510/745-7715. Contact information for offices in Europe and Japan is available on the Web site. The latest information on Linux support for DAC960 PCI RAID Controllers, as well as the most recent release of this driver, will always be available from my Linux Home Page at URL "http://www.dandelion.com/Linux/". The Linux DAC960 driver supports all current DAC960 PCI family controllers including the AcceleRAID models, as well as the eXtremeRAID 1100; see below for a complete list. For simplicity, in most places this documentation refers to DAC960 generically rather than explicitly listing all the models. Bug reports should be sent via electronic mail to "lnz@dandelion.com". Please include with the bug report the complete configuration messages reported by the driver at startup, along with any subsequent system messages relevant to the controller's operation, and a detailed description of your system's hardware configuration. Please consult the DAC960 RAID controller documentation for detailed information regarding installation and configuration of the controllers. This document primarily provides information specific to the Linux DAC960 support. DRIVER FEATURES The DAC960 RAID controllers are supported solely as high performance RAID controllers, not as interfaces to arbitrary SCSI devices. The Linux DAC960 driver operates at the block device level, the same level as the SCSI and IDE drivers. Unlike other RAID controllers currently supported on Linux, the DAC960 driver is not dependent on the SCSI subsystem, and hence avoids all the complexity and unnecessary code that would be associated with an implementation as a SCSI driver. The DAC960 driver is designed for as high a performance as possible with no compromises or extra code for compatibility with lower performance devices. The DAC960 driver includes extensive error logging and online configuration management capabilities. Except for initial configuration of the controller and adding new disk drives, most everything can be handled from Linux while the system is operational. The DAC960 driver is architected to support up to 8 controllers per system. Each DAC960 controller can support up to 15 disk drives per channel, for a maximum of 45 drives on a three channel controller. The drives installed on a controller are divided into one or more "Drive Groups", and then each Drive Group is subdivided further into 1 to 32 "Logical Drives". Each Logical Drive has a specific RAID Level and caching policy associated with it, and it appears to Linux as a single block device. Logical Drives are further subdivided into up to 7 partitions through the normal Linux and PC disk partitioning schemes. Logical Drives are also known as "System Drives", and Drive Groups are also called "Packs". Both terms are in use in the Mylex documentation; I have chosen to standardize on the more generic "Logical Drive" and "Drive Group". DAC960 RAID disk devices are named in the style of the Device File System (DEVFS). The device corresponding to Logical Drive D on Controller C is referred to as /dev/rd/cCdD, and the partitions are called /dev/rd/cCdDp1 through /dev/rd/cCdDp7. For example, partition 3 of Logical Drive 5 on Controller 2 is referred to as /dev/rd/c2d5p3. Note that unlike with SCSI disks the device names will not change in the event of a disk drive failure. The DAC960 driver is assigned major numbers 48 - 55 with one major number per controller. The 8 bits of minor number are divided into 5 bits for the Logical Drive and 3 bits for the partition. SUPPORTED DAC960/DAC1100 PCI RAID CONTROLLERS The following list comprises the supported DAC960 and DAC1100 PCI RAID Controllers as of the date of this document. It is recommended that anyone purchasing a Mylex PCI RAID Controller not in the following table contact the author beforehand to verify that it is or will be supported. The eXtremeRAID 2000, eXtremeRAID 3000, and AcceleRAID 352 have an entirely new firmware interface and are not yet supported by this driver. eXtremeRAID 1100 (DAC1164P) 3 Wide Ultra-2/LVD SCSI channels 233MHz StrongARM SA 110 Processor 64 Bit PCI (backward compatible with 32 Bit PCI slots) 16MB/32MB/64MB Parity SDRAM Memory with Battery Backup AcceleRAID 250 (DAC960PTL1) Uses onboard Symbios SCSI chips on certain motherboards Also includes one onboard Wide Ultra-2/LVD SCSI Channel 66MHz Intel i960RD RISC Processor 4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory AcceleRAID 200 (DAC960PTL0) Uses onboard Symbios SCSI chips on certain motherboards Includes no onboard SCSI Channels 66MHz Intel i960RD RISC Processor 4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory AcceleRAID 150 (DAC960PRL) Uses onboard Symbios SCSI chips on certain motherboards Also includes one onboard Wide Ultra-2/LVD SCSI Channel 33MHz Intel i960RP RISC Processor 4MB Parity EDO Memory DAC960PJ 1/2/3 Wide Ultra SCSI-3 Channels 66MHz Intel i960RD RISC Processor 4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory DAC960PG 1/2/3 Wide Ultra SCSI-3 Channels 33MHz Intel i960RP RISC Processor 4MB/8MB ECC EDO Memory DAC960PU 1/2/3 Wide Ultra SCSI-3 Channels Intel i960CF RISC Processor 4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory DAC960PD 1/2/3 Wide Fast SCSI-2 Channels Intel i960CF RISC Processor 4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory DAC960PL 1/2/3 Wide Fast SCSI-2 Channels Intel i960 RISC Processor 2MB/4MB/8MB/16MB/32MB DRAM Memory For the eXtremeRAID 1100, firmware version 5.06-0-52 or above is required. For the AcceleRAID 250, 200, and 150, firmware version 4.06-0-57 or above is required. For the DAC960PJ and DAC960PG, firmware version 4.06-0-00 or above is required. For the DAC960PU, DAC960PD, and DAC960PL, firmware version 3.51-0-04 or above is required. Note that earlier revisions of the DAC960PU, DAC960PD, and DAC960PL controllers were delivered with version 2.xx firmware. Version 2.xx firmware is not supported by this driver and no support is envisioned. Contact Mylex RAID Technical Support to inquire about upgrading controllers with version 2.xx firmware to version 3.51-0-04. Upgrading to version 3.xx firmware requires installation of higher capacity Flash ROM chips, and not all DAC960PD and DAC960PL controllers can be upgraded. Please note that not all SCSI disk drives are suitable for use with DAC960 controllers, and only particular firmware versions of any given model may actually function correctly. Similarly, not all motherboards have a BIOS that properly initializes the AcceleRAID 250, AcceleRAID 200, AcceleRAID 150, DAC960PJ, and DAC960PG because the Intel i960RD/RP is a multi-function device. If in doubt, contact Mylex RAID Technical Support (support@mylex.com) to verify compatibility. Mylex makes available a hard disk compatibility list by FTP at ftp://ftp.mylex.com/pub/dac960/diskcomp.html. DRIVER INSTALLATION This distribution was prepared for Linux kernel version 2.2.14 or 2.0.38. To install the DAC960 RAID driver, you may use the following commands, replacing "/usr/src" with wherever you keep your Linux kernel source tree: cd /usr/src tar -xvzf DAC960-2.2.5.tar.gz (or DAC960-2.0.5.tar.gz) mv README.DAC960 linux/Documentation mv DAC960.[ch] linux/drivers/block patch -p0 < DAC960.patch (driver 2.0.5 only) cd linux make config make depend make bzImage (or zImage) Then install "arch/i386/boot/bzImage" or "arch/i386/boot/zImage" as your standard kernel, run lilo if appropriate, and reboot. To create the necessary devices in /dev, the "make_rd" script included in "DAC960-Utilities.tar.gz" from http://www.dandelion.com/Linux/ may be used. LILO 21 and FDISK v2.9 include DAC960 support; also included in this archive are patches to LILO 20 and FDISK v2.8 that add DAC960 support, along with statically linked executables of LILO and FDISK. This modified version of LILO will allow booting from a DAC960 controller and/or mounting the root file system from a DAC960. Red Hat Linux 6.0 and SuSE Linux 6.1 include support for Mylex PCI RAID controllers. Installing directly onto a DAC960 may be problematic from other Linux distributions until their installation utilities are updated. INSTALLATION NOTES Before installing Linux or adding DAC960 logical drives to an existing Linux system, the controller must first be configured to provide one or more logical drives using the BIOS Configuration Utility or DACCF. Please note that since there are only at most 6 usable partitions on each logical drive, systems requiring more partitions should subdivide a drive group into multiple logical drives, each of which can have up to 6 partitions. Also, note that with large disk arrays it is advisable to enable the 8GB BIOS Geometry (255/63) rather than accepting the default 2GB BIOS Geometry (128/32); failing to so do will cause the logical drive geometry to have more than 65535 cylinders which will make it impossible for FDISK to be used properly. The 8GB BIOS Geometry can be enabled by configuring the DAC960 BIOS, which is accessible via Alt-M during the BIOS initialization sequence. For maximum performance and the most efficient E2FSCK performance, it is recommended that EXT2 file systems be built with a 4KB block size and 16 block stride to match the DAC960 controller's 64KB default stripe size. The command "mke2fs -b 4096 -R stride=16 <device>" is appropriate. Unless there will be a large number of small files on the file systems, it is also beneficial to add the "-i 16384" option to increase the bytes per inode parameter thereby reducing the file system metadata. Finally, on systems that will only be run with Linux 2.2 or later kernels it is beneficial to enable sparse superblocks with the "-s 1" option. DAC960 ANNOUNCEMENTS MAILING LIST The DAC960 Announcements Mailing List provides a forum for informing Linux users of new driver releases and other announcements regarding Linux support for DAC960 PCI RAID Controllers. To join the mailing list, send a message to "dac960-announce-request@dandelion.com" with the line "subscribe" in the message body. CONTROLLER CONFIGURATION AND STATUS MONITORING The DAC960 RAID controllers running firmware 4.06 or above include a Background Initialization facility so that system downtime is minimized both for initial installation and subsequent configuration of additional storage. The BIOS Configuration Utility (accessible via Alt-R during the BIOS initialization sequence) is used to quickly configure the controller, and then the logical drives that have been created are available for immediate use even while they are still being initialized by the controller. The primary need for online configuration and status monitoring is then to avoid system downtime when disk drives fail and must be replaced. Mylex's online monitoring and configuration utilities are being ported to Linux and will become available at some point in the future. Note that with a SAF-TE (SCSI Accessed Fault-Tolerant Enclosure) enclosure, the controller is able to rebuild failed drives automatically as soon as a drive replacement is made available. The primary interfaces for controller configuration and status monitoring are special files created in the /proc/rd/... hierarchy along with the normal system console logging mechanism. Whenever the system is operating, the DAC960 driver queries each controller for status information every 10 seconds, and checks for additional conditions every 60 seconds. The initial status of each controller is always available for controller N in /proc/rd/cN/initial_status, and the current status as of the last status monitoring query is available in /proc/rd/cN/current_status. In addition, status changes are also logged by the driver to the system console and will appear in the log files maintained by syslog. The progress of asynchronous rebuild or consistency check operations is also available in /proc/rd/cN/current_status, and progress messages are logged to the system console at most every 60 seconds. Starting with the 2.2.3/2.0.3 versions of the driver, the status information available in /proc/rd/cN/initial_status and /proc/rd/cN/current_status has been augmented to include the vendor, model, revision, and serial number (if available) for each physical device found connected to the controller: ***** DAC960 RAID Driver Version 2.2.3 of 19 August 1999 ***** Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com> Configuring Mylex DAC960PRL PCI RAID Controller Firmware Version: 4.07-0-07, Channels: 1, Memory Size: 16MB PCI Bus: 1, Device: 4, Function: 1, I/O Address: Unassigned PCI Address: 0xFE300000 mapped at 0xA0800000, IRQ Channel: 21 Controller Queue Depth: 128, Maximum Blocks per Command: 128 Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33 Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63 SAF-TE Enclosure Management Enabled Physical Devices: 0:0 Vendor: IBM Model: DRVS09D Revision: 0270 Serial Number: 68016775HA Disk Status: Online, 17928192 blocks 0:1 Vendor: IBM Model: DRVS09D Revision: 0270 Serial Number: 68004E53HA Disk Status: Online, 17928192 blocks 0:2 Vendor: IBM Model: DRVS09D Revision: 0270 Serial Number: 13013935HA Disk Status: Online, 17928192 blocks 0:3 Vendor: IBM Model: DRVS09D Revision: 0270 Serial Number: 13016897HA Disk Status: Online, 17928192 blocks 0:4 Vendor: IBM Model: DRVS09D Revision: 0270 Serial Number: 68019905HA Disk Status: Online, 17928192 blocks 0:5 Vendor: IBM Model: DRVS09D Revision: 0270 Serial Number: 68012753HA Disk Status: Online, 17928192 blocks 0:6 Vendor: ESG-SHV Model: SCA HSBP M6 Revision: 0.61 Logical Drives: /dev/rd/c0d0: RAID-5, Online, 89640960 blocks, Write Thru No Rebuild or Consistency Check in Progress To simplify the monitoring process for custom software, the special file /proc/rd/status returns "OK" when all DAC960 controllers in the system are operating normally and no failures have occurred, or "ALERT" if any logical drives are offline or critical or any non-standby physical drives are dead. Configuration commands for controller N are available via the special file /proc/rd/cN/user_command. A human readable command can be written to this special file to initiate a configuration operation, and the results of the operation can then be read back from the special file in addition to being logged to the system console. The shell command sequence echo "<configuration-command>" > /proc/rd/c0/user_command cat /proc/rd/c0/user_command is typically used to execute configuration commands. The configuration commands are: flush-cache The "flush-cache" command flushes the controller's cache. The system automatically flushes the cache at shutdown or if the driver module is unloaded, so this command is only needed to be certain a write back cache is flushed to disk before the system is powered off by a command to a UPS. Note that the flush-cache command also stops an asynchronous rebuild or consistency check, so it should not be used except when the system is being halted. kill <channel>:<target-id> The "kill" command marks the physical drive <channel>:<target-id> as DEAD. This command is provided primarily for testing, and should not be used during normal system operation. make-online <channel>:<target-id> The "make-online" command changes the physical drive <channel>:<target-id> from status DEAD to status ONLINE. In cases where multiple physical drives have been killed simultaneously, this command may be used to bring them back online, after which a consistency check is advisable. Warning: make-online should only be used on a dead physical drive that is an active part of a drive group, never on a standby drive. make-standby <channel>:<target-id> The "make-standby" command changes physical drive <channel>:<target-id> from status DEAD to status STANDBY. It should only be used in cases where a dead drive was replaced after an automatic rebuild was performed onto a standby drive. It cannot be used to add a standby drive to the controller configuration if one was not created initially; the BIOS Configuration Utility must be used for that currently. rebuild <channel>:<target-id> The "rebuild" command initiates an asynchronous rebuild onto physical drive <channel>:<target-id>. It should only be used when a dead drive has been replaced. check-consistency <logical-drive-number> The "check-consistency" command initiates an asynchronous consistency check of <logical-drive-number> with automatic restoration. It can be used whenever it is desired to verify the consistency of the redundancy information. cancel-rebuild cancel-consistency-check The "cancel-rebuild" and "cancel-consistency-check" commands cancel any rebuild or consistency check operations previously initiated. EXAMPLE I - DRIVE FAILURE WITHOUT A STANDBY DRIVE The following annotated logs demonstrate the controller configuration and and online status monitoring capabilities of the Linux DAC960 Driver. The test configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a DAC960PJ controller. The physical drives are configured into a single drive group without a standby drive, and the drive group has been configured into two logical drives, one RAID-5 and one RAID-6. Note that these logs are from an earlier version of the driver and the messages have changed somewhat with newer releases, but the functionality remains similar. First, here is the current status of the RAID configuration: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 ***** Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com> Configuring Mylex DAC960PJ PCI RAID Controller Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9 Controller Queue Depth: 128, Maximum Blocks per Command: 128 Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33 Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63 Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Online, 2201600 blocks 1:2 - Disk: Online, 2201600 blocks 1:3 - Disk: Online, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru /dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru No Rebuild or Consistency Check in Progress gwynedd:/u/lnz# cat /proc/rd/status OK The above messages indicate that everything is healthy, and /proc/rd/status returns "OK" indicating that there are no problems with any DAC960 controller in the system. For demonstration purposes, while I/O is active Physical Drive 1:1 is now disconnected, simulating a drive failure. The failure is noted by the driver within 10 seconds of the controller's having detected it, and the driver logs the following console status messages indicating that Logical Drives 0 and 1 are now CRITICAL as a result of Physical Drive 1:1 being DEAD: DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02 DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02 DAC960#0: Physical Drive 1:1 killed because of timeout on SCSI command DAC960#0: Physical Drive 1:1 is now DEAD DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL The Sense Keys logged here are just Check Condition / Unit Attention conditions arising from a SCSI bus reset that is forced by the controller during its error recovery procedures. Concurrently with the above, the driver status available from /proc/rd also reflects the drive failure. The status message in /proc/rd/status has changed from "OK" to "ALERT": gwynedd:/u/lnz# cat /proc/rd/status ALERT and /proc/rd/c0/current_status has been updated: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ... Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Dead, 2201600 blocks 1:2 - Disk: Online, 2201600 blocks 1:3 - Disk: Online, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru /dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru No Rebuild or Consistency Check in Progress Since there are no standby drives configured, the system can continue to access the logical drives in a performance degraded mode until the failed drive is replaced and a rebuild operation completed to restore the redundancy of the logical drives. Once Physical Drive 1:1 is replaced with a properly functioning drive, or if the physical drive was killed without having failed (e.g., due to electrical problems on the SCSI bus), the user can instruct the controller to initiate a rebuild operation onto the newly replaced drive: gwynedd:/u/lnz# echo "rebuild 1:1" > /proc/rd/c0/user_command gwynedd:/u/lnz# cat /proc/rd/c0/user_command Rebuild of Physical Drive 1:1 Initiated The echo command instructs the controller to initiate an asynchronous rebuild operation onto Physical Drive 1:1, and the status message that results from the operation is then available for reading from /proc/rd/c0/user_command, as well as being logged to the console by the driver. Within 10 seconds of this command the driver logs the initiation of the asynchronous rebuild operation: DAC960#0: Rebuild of Physical Drive 1:1 Initiated DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01 DAC960#0: Physical Drive 1:1 is now WRITE-ONLY DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 1% completed and /proc/rd/c0/current_status is updated: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ... Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Write-Only, 2201600 blocks 1:2 - Disk: Online, 2201600 blocks 1:3 - Disk: Online, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru /dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 6% completed As the rebuild progresses, the current status in /proc/rd/c0/current_status is updated every 10 seconds: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ... Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Write-Only, 2201600 blocks 1:2 - Disk: Online, 2201600 blocks 1:3 - Disk: Online, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru /dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 15% completed and every minute a progress message is logged to the console by the driver: DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 32% completed DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 63% completed DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 94% completed DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 94% completed Finally, the rebuild completes successfully. The driver logs the status of the logical and physical drives and the rebuild completion: DAC960#0: Rebuild Completed Successfully DAC960#0: Physical Drive 1:1 is now ONLINE DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE /proc/rd/c0/current_status is updated: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ... Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Online, 2201600 blocks 1:2 - Disk: Online, 2201600 blocks 1:3 - Disk: Online, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru /dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru Rebuild Completed Successfully and /proc/rd/status indicates that everything is healthy once again: gwynedd:/u/lnz# cat /proc/rd/status OK EXAMPLE II - DRIVE FAILURE WITH A STANDBY DRIVE The following annotated logs demonstrate the controller configuration and and online status monitoring capabilities of the Linux DAC960 Driver. The test configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a DAC960PJ controller. The physical drives are configured into a single drive group with a standby drive, and the drive group has been configured into two logical drives, one RAID-5 and one RAID-6. Note that these logs are from an earlier version of the driver and the messages have changed somewhat with newer releases, but the functionality remains similar. First, here is the current status of the RAID configuration: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 ***** Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com> Configuring Mylex DAC960PJ PCI RAID Controller Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9 Controller Queue Depth: 128, Maximum Blocks per Command: 128 Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33 Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63 Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Online, 2201600 blocks 1:2 - Disk: Online, 2201600 blocks 1:3 - Disk: Standby, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru /dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru No Rebuild or Consistency Check in Progress gwynedd:/u/lnz# cat /proc/rd/status OK The above messages indicate that everything is healthy, and /proc/rd/status returns "OK" indicating that there are no problems with any DAC960 controller in the system. For demonstration purposes, while I/O is active Physical Drive 1:2 is now disconnected, simulating a drive failure. The failure is noted by the driver within 10 seconds of the controller's having detected it, and the driver logs the following console status messages: DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02 DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02 DAC960#0: Physical Drive 1:2 killed because of timeout on SCSI command DAC960#0: Physical Drive 1:2 is now DEAD DAC960#0: Physical Drive 1:2 killed because it was removed DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL Since a standby drive is configured, the controller automatically begins rebuilding onto the standby drive: DAC960#0: Physical Drive 1:3 is now WRITE-ONLY DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed Concurrently with the above, the driver status available from /proc/rd also reflects the drive failure and automatic rebuild. The status message in /proc/rd/status has changed from "OK" to "ALERT": gwynedd:/u/lnz# cat /proc/rd/status ALERT and /proc/rd/c0/current_status has been updated: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ... Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Online, 2201600 blocks 1:2 - Disk: Dead, 2201600 blocks 1:3 - Disk: Write-Only, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru /dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed As the rebuild progresses, the current status in /proc/rd/c0/current_status is updated every 10 seconds: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ... Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Online, 2201600 blocks 1:2 - Disk: Dead, 2201600 blocks 1:3 - Disk: Write-Only, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru /dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed and every minute a progress message is logged on the console by the driver: DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 76% completed DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 66% completed DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 84% completed Finally, the rebuild completes successfully. The driver logs the status of the logical and physical drives and the rebuild completion: DAC960#0: Rebuild Completed Successfully DAC960#0: Physical Drive 1:3 is now ONLINE DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE /proc/rd/c0/current_status is updated: ***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 ***** Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com> Configuring Mylex DAC960PJ PCI RAID Controller Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9 Controller Queue Depth: 128, Maximum Blocks per Command: 128 Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33 Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63 Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Online, 2201600 blocks 1:2 - Disk: Dead, 2201600 blocks 1:3 - Disk: Online, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru /dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru Rebuild Completed Successfully and /proc/rd/status indicates that everything is healthy once again: gwynedd:/u/lnz# cat /proc/rd/status OK Note that the absence of a viable standby drive does not create an "ALERT" status. Once dead Physical Drive 1:2 has been replaced, the controller must be told that this has occurred and that the newly replaced drive should become the new standby drive: gwynedd:/u/lnz# echo "make-standby 1:2" > /proc/rd/c0/user_command gwynedd:/u/lnz# cat /proc/rd/c0/user_command Make Standby of Physical Drive 1:2 Succeeded The echo command instructs the controller to make Physical Drive 1:2 into a standby drive, and the status message that results from the operation is then available for reading from /proc/rd/c0/user_command, as well as being logged to the console by the driver. Within 60 seconds of this command the driver logs: DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01 DAC960#0: Physical Drive 1:2 is now STANDBY DAC960#0: Make Standby of Physical Drive 1:2 Succeeded and /proc/rd/c0/current_status is updated: gwynedd:/u/lnz# cat /proc/rd/c0/current_status ... Physical Devices: 0:1 - Disk: Online, 2201600 blocks 0:2 - Disk: Online, 2201600 blocks 0:3 - Disk: Online, 2201600 blocks 1:1 - Disk: Online, 2201600 blocks 1:2 - Disk: Standby, 2201600 blocks 1:3 - Disk: Online, 2201600 blocks Logical Drives: /dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru /dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru Rebuild Completed Successfully |