Loading...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 | .. SPDX-License-Identifier: GPL-2.0 ================================================ Cirrus Logic LAN CS8900/CS8920 Ethernet Adapters ================================================ .. note:: This document was contributed by Cirrus Logic for kernel 2.2.5. This version has been updated for 2.3.48 by Andrew Morton. Still, this is too outdated! A major cleanup is needed here. Cirrus make a copy of this driver available at their website, as described below. In general, you should use the driver version which comes with your Linux distribution. Linux Network Interface Driver ver. 2.00 <kernel 2.3.48> .. TABLE OF CONTENTS 1.0 CIRRUS LOGIC LAN CS8900/CS8920 ETHERNET ADAPTERS 1.1 Product Overview 1.2 Driver Description 1.2.1 Driver Name 1.2.2 File in the Driver Package 1.3 System Requirements 1.4 Licensing Information 2.0 ADAPTER INSTALLATION and CONFIGURATION 2.1 CS8900-based Adapter Configuration 2.2 CS8920-based Adapter Configuration 3.0 LOADING THE DRIVER AS A MODULE 4.0 COMPILING THE DRIVER 4.1 Compiling the Driver as a Loadable Module 4.2 Compiling the driver to support memory mode 4.3 Compiling the driver to support Rx DMA 5.0 TESTING AND TROUBLESHOOTING 5.1 Known Defects and Limitations 5.2 Testing the Adapter 5.2.1 Diagnostic Self-Test 5.2.2 Diagnostic Network Test 5.3 Using the Adapter's LEDs 5.4 Resolving I/O Conflicts 6.0 TECHNICAL SUPPORT 6.1 Contacting Cirrus Logic's Technical Support 6.2 Information Required Before Contacting Technical Support 6.3 Obtaining the Latest Driver Version 6.4 Current maintainer 6.5 Kernel boot parameters 1. Cirrus Logic LAN CS8900/CS8920 Ethernet Adapters =================================================== 1.1. Product Overview ===================== The CS8900-based ISA Ethernet Adapters from Cirrus Logic follow IEEE 802.3 standards and support half or full-duplex operation in ISA bus computers on 10 Mbps Ethernet networks. The adapters are designed for operation in 16-bit ISA or EISA bus expansion slots and are available in 10BaseT-only or 3-media configurations (10BaseT, 10Base2, and AUI for 10Base-5 or fiber networks). CS8920-based adapters are similar to the CS8900-based adapter with additional features for Plug and Play (PnP) support and Wakeup Frame recognition. As such, the configuration procedures differ somewhat between the two types of adapters. Refer to the "Adapter Configuration" section for details on configuring both types of adapters. 1.2. Driver Description ======================= The CS8900/CS8920 Ethernet Adapter driver for Linux supports the Linux v2.3.48 or greater kernel. It can be compiled directly into the kernel or loaded at run-time as a device driver module. 1.2.1 Driver Name: cs89x0 1.2.2 Files in the Driver Archive: The files in the driver at Cirrus' website include: =================== ==================================================== readme.txt this file build batch file to compile cs89x0.c. cs89x0.c driver C code cs89x0.h driver header file cs89x0.o pre-compiled module (for v2.2.5 kernel) config/Config.in sample file to include cs89x0 driver in the kernel. config/Makefile sample file to include cs89x0 driver in the kernel. config/Space.c sample file to include cs89x0 driver in the kernel. =================== ==================================================== 1.3. System Requirements ------------------------ The following hardware is required: * Cirrus Logic LAN (CS8900/20-based) Ethernet ISA Adapter * IBM or IBM-compatible PC with: * An 80386 or higher processor * 16 bytes of contiguous IO space available between 210h - 370h * One available IRQ (5,10,11,or 12 for the CS8900, 3-7,9-15 for CS8920). * Appropriate cable (and connector for AUI, 10BASE-2) for your network topology. The following software is required: * LINUX kernel version 2.3.48 or higher * CS8900/20 Setup Utility (DOS-based) * LINUX kernel sources for your kernel (if compiling into kernel) * GNU Toolkit (gcc and make) v2.6 or above (if compiling into kernel or a module) 1.4. Licensing Information -------------------------- This program is free software; you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, version 1. This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. For a full copy of the GNU General Public License, write to the Free Software Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA. 2. Adapter Installation and Configuration ========================================= Both the CS8900 and CS8920-based adapters can be configured using parameters stored in an on-board EEPROM. You must use the DOS-based CS8900/20 Setup Utility if you want to change the adapter's configuration in EEPROM. When loading the driver as a module, you can specify many of the adapter's configuration parameters on the command-line to override the EEPROM's settings or for interface configuration when an EEPROM is not used. (CS8920-based adapters must use an EEPROM.) See Section 3.0 LOADING THE DRIVER AS A MODULE. Since the CS8900/20 Setup Utility is a DOS-based application, you must install and configure the adapter in a DOS-based system using the CS8900/20 Setup Utility before installation in the target LINUX system. (Not required if installing a CS8900-based adapter and the default configuration is acceptable.) 2.1. CS8900-based Adapter Configuration --------------------------------------- CS8900-based adapters shipped from Cirrus Logic have been configured with the following "default" settings:: Operation Mode: Memory Mode IRQ: 10 Base I/O Address: 300 Memory Base Address: D0000 Optimization: DOS Client Transmission Mode: Half-duplex BootProm: None Media Type: Autodetect (3-media cards) or 10BASE-T (10BASE-T only adapter) You should only change the default configuration settings if conflicts with another adapter exists. To change the adapter's configuration, run the CS8900/20 Setup Utility. 2.2. CS8920-based Adapter Configuration --------------------------------------- CS8920-based adapters are shipped from Cirrus Logic configured as Plug and Play (PnP) enabled. However, since the cs89x0 driver does NOT support PnP, you must install the CS8920 adapter in a DOS-based PC and run the CS8900/20 Setup Utility to disable PnP and configure the adapter before installation in the target Linux system. Failure to do this will leave the adapter inactive and the driver will be unable to communicate with the adapter. :: **************************************************************** * CS8920-BASED ADAPTERS: * * * * CS8920-BASED ADAPTERS ARE PLUG and PLAY ENABLED BY DEFAULT. * * THE CS89X0 DRIVER DOES NOT SUPPORT PnP. THEREFORE, YOU MUST * * RUN THE CS8900/20 SETUP UTILITY TO DISABLE PnP SUPPORT AND * * TO ACTIVATE THE ADAPTER. * **************************************************************** 3. Loading the Driver as a Module ================================= If the driver is compiled as a loadable module, you can load the driver module with the 'modprobe' command. Many of the adapter's configuration parameters can be specified as command-line arguments to the load command. This facility provides a means to override the EEPROM's settings or for interface configuration when an EEPROM is not used. Example:: insmod cs89x0.o io=0x200 irq=0xA media=aui This example loads the module and configures the adapter to use an IO port base address of 200h, interrupt 10, and use the AUI media connection. The following configuration options are available on the command line:: io=### - specify IO address (200h-360h) irq=## - specify interrupt level use_dma=1 - Enable DMA dma=# - specify dma channel (Driver is compiled to support Rx DMA only) dmasize=# (16 or 64) - DMA size 16K or 64K. Default value is set to 16. media=rj45 - specify media type or media=bnc or media=aui or media=auto duplex=full - specify forced half/full/autonegotiate duplex or duplex=half or duplex=auto debug=# - debug level (only available if the driver was compiled for debugging) **Notes:** a) If an EEPROM is present, any specified command-line parameter will override the corresponding configuration value stored in EEPROM. b) The "io" parameter must be specified on the command-line. c) The driver's hardware probe routine is designed to avoid writing to I/O space until it knows that there is a cs89x0 card at the written addresses. This could cause problems with device probing. To avoid this behaviour, add one to the ``io=`` module parameter. This doesn't actually change the I/O address, but it is a flag to tell the driver to partially initialise the hardware before trying to identify the card. This could be dangerous if you are not sure that there is a cs89x0 card at the provided address. For example, to scan for an adapter located at IO base 0x300, specify an IO address of 0x301. d) The "duplex=auto" parameter is only supported for the CS8920. e) The minimum command-line configuration required if an EEPROM is not present is: io irq media type (no autodetect) f) The following additional parameters are CS89XX defaults (values used with no EEPROM or command-line argument). * DMA Burst = enabled * IOCHRDY Enabled = enabled * UseSA = enabled * CS8900 defaults to half-duplex if not specified on command-line * CS8920 defaults to autoneg if not specified on command-line * Use reset defaults for other config parameters * dma_mode = 0 g) You can use ifconfig to set the adapter's Ethernet address. h) Many Linux distributions use the 'modprobe' command to load modules. This program uses the '/etc/conf.modules' file to determine configuration information which is passed to a driver module when it is loaded. All the configuration options which are described above may be placed within /etc/conf.modules. For example:: > cat /etc/conf.modules ... alias eth0 cs89x0 options cs89x0 io=0x0200 dma=5 use_dma=1 ... In this example we are telling the module system that the ethernet driver for this machine should use the cs89x0 driver. We are asking 'modprobe' to pass the 'io', 'dma' and 'use_dma' arguments to the driver when it is loaded. i) Cirrus recommend that the cs89x0 use the ISA DMA channels 5, 6 or 7. You will probably find that other DMA channels will not work. j) The cs89x0 supports DMA for receiving only. DMA mode is significantly more efficient. Flooding a 400 MHz Celeron machine with large ping packets consumes 82% of its CPU capacity in non-DMA mode. With DMA this is reduced to 45%. k) If your Linux kernel was compiled with inbuilt plug-and-play support you will be able to find information about the cs89x0 card with the command:: cat /proc/isapnp l) If during DMA operation you find erratic behavior or network data corruption you should use your PC's BIOS to slow the EISA bus clock. m) If the cs89x0 driver is compiled directly into the kernel (non-modular) then its I/O address is automatically determined by ISA bus probing. The IRQ number, media options, etc are determined from the card's EEPROM. n) If the cs89x0 driver is compiled directly into the kernel, DMA mode may be selected by providing the kernel with a boot option 'cs89x0_dma=N' where 'N' is the desired DMA channel number (5, 6 or 7). Kernel boot options may be provided on the LILO command line:: LILO boot: linux cs89x0_dma=5 or they may be placed in /etc/lilo.conf:: image=/boot/bzImage-2.3.48 append="cs89x0_dma=5" label=linux root=/dev/hda5 read-only The DMA Rx buffer size is hardwired to 16 kbytes in this mode. (64k mode is not available). 4. Compiling the Driver ======================= The cs89x0 driver can be compiled directly into the kernel or compiled into a loadable device driver module. Just use the standard way to configure the driver and compile the Kernel. 4.1. Compiling the Driver to Support Rx DMA ------------------------------------------- The compile-time optionality for DMA was removed in the 2.3 kernel series. DMA support is now unconditionally part of the driver. It is enabled by the 'use_dma=1' module option. 5. Testing and Troubleshooting ============================== 5.1. Known Defects and Limitations ---------------------------------- Refer to the RELEASE.TXT file distributed as part of this archive for a list of known defects, driver limitations, and work arounds. 5.2. Testing the Adapter ------------------------ Once the adapter has been installed and configured, the diagnostic option of the CS8900/20 Setup Utility can be used to test the functionality of the adapter and its network connection. Use the diagnostics 'Self Test' option to test the functionality of the adapter with the hardware configuration you have assigned. You can use the diagnostics 'Network Test' to test the ability of the adapter to communicate across the Ethernet with another PC equipped with a CS8900/20-based adapter card (it must also be running the CS8900/20 Setup Utility). .. note:: The Setup Utility's diagnostics are designed to run in a DOS-only operating system environment. DO NOT run the diagnostics from a DOS or command prompt session under Windows 95, Windows NT, OS/2, or other operating system. To run the diagnostics tests on the CS8900/20 adapter: 1. Boot DOS on the PC and start the CS8900/20 Setup Utility. 2. The adapter's current configuration is displayed. Hit the ENTER key to get to the main menu. 4. Select 'Diagnostics' (ALT-G) from the main menu. * Select 'Self-Test' to test the adapter's basic functionality. * Select 'Network Test' to test the network connection and cabling. 5.2.1. Diagnostic Self-test ^^^^^^^^^^^^^^^^^^^^^^^^^^^ The diagnostic self-test checks the adapter's basic functionality as well as its ability to communicate across the ISA bus based on the system resources assigned during hardware configuration. The following tests are performed: * IO Register Read/Write Test The IO Register Read/Write test insures that the CS8900/20 can be accessed in IO mode, and that the IO base address is correct. * Shared Memory Test The Shared Memory test insures the CS8900/20 can be accessed in memory mode and that the range of memory addresses assigned does not conflict with other devices in the system. * Interrupt Test The Interrupt test insures there are no conflicts with the assigned IRQ signal. * EEPROM Test The EEPROM test insures the EEPROM can be read. * Chip RAM Test The Chip RAM test insures the 4K of memory internal to the CS8900/20 is working properly. * Internal Loop-back Test The Internal Loop Back test insures the adapter's transmitter and receiver are operating properly. If this test fails, make sure the adapter's cable is connected to the network (check for LED activity for example). * Boot PROM Test The Boot PROM test insures the Boot PROM is present, and can be read. Failure indicates the Boot PROM was not successfully read due to a hardware problem or due to a conflicts on the Boot PROM address assignment. (Test only applies if the adapter is configured to use the Boot PROM option.) Failure of a test item indicates a possible system resource conflict with another device on the ISA bus. In this case, you should use the Manual Setup option to reconfigure the adapter by selecting a different value for the system resource that failed. 5.2.2. Diagnostic Network Test ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The Diagnostic Network Test verifies a working network connection by transferring data between two CS8900/20 adapters installed in different PCs on the same network. (Note: the diagnostic network test should not be run between two nodes across a router.) This test requires that each of the two PCs have a CS8900/20-based adapter installed and have the CS8900/20 Setup Utility running. The first PC is configured as a Responder and the other PC is configured as an Initiator. Once the Initiator is started, it sends data frames to the Responder which returns the frames to the Initiator. The total number of frames received and transmitted are displayed on the Initiator's display, along with a count of the number of frames received and transmitted OK or in error. The test can be terminated anytime by the user at either PC. To setup the Diagnostic Network Test: 1. Select a PC with a CS8900/20-based adapter and a known working network connection to act as the Responder. Run the CS8900/20 Setup Utility and select 'Diagnostics -> Network Test -> Responder' from the main menu. Hit ENTER to start the Responder. 2. Return to the PC with the CS8900/20-based adapter you want to test and start the CS8900/20 Setup Utility. 3. From the main menu, Select 'Diagnostic -> Network Test -> Initiator'. Hit ENTER to start the test. You may stop the test on the Initiator at any time while allowing the Responder to continue running. In this manner, you can move to additional PCs and test them by starting the Initiator on another PC without having to stop/start the Responder. 5.3. Using the Adapter's LEDs ----------------------------- The 2 and 3-media adapters have two LEDs visible on the back end of the board located near the 10Base-T connector. Link Integrity LED: A "steady" ON of the green LED indicates a valid 10Base-T connection. (Only applies to 10Base-T. The green LED has no significance for a 10Base-2 or AUI connection.) TX/RX LED: The yellow LED lights briefly each time the adapter transmits or receives data. (The yellow LED will appear to "flicker" on a typical network.) 5.4. Resolving I/O Conflicts ---------------------------- An IO conflict occurs when two or more adapter use the same ISA resource (IO address, memory address or IRQ). You can usually detect an IO conflict in one of four ways after installing and or configuring the CS8900/20-based adapter: 1. The system does not boot properly (or at all). 2. The driver cannot communicate with the adapter, reporting an "Adapter not found" error message. 3. You cannot connect to the network or the driver will not load. 4. If you have configured the adapter to run in memory mode but the driver reports it is using IO mode when loading, this is an indication of a memory address conflict. If an IO conflict occurs, run the CS8900/20 Setup Utility and perform a diagnostic self-test. Normally, the ISA resource in conflict will fail the self-test. If so, reconfigure the adapter selecting another choice for the resource in conflict. Run the diagnostics again to check for further IO conflicts. In some cases, such as when the PC will not boot, it may be necessary to remove the adapter and reconfigure it by installing it in another PC to run the CS8900/20 Setup Utility. Once reinstalled in the target system, run the diagnostics self-test to ensure the new configuration is free of conflicts before loading the driver again. When manually configuring the adapter, keep in mind the typical ISA system resource usage as indicated in the tables below. :: I/O Address Device IRQ Device ----------- -------- --- -------- 200-20F Game I/O adapter 3 COM2, Bus Mouse 230-23F Bus Mouse 4 COM1 270-27F LPT3: third parallel port 5 LPT2 2F0-2FF COM2: second serial port 6 Floppy Disk controller 320-32F Fixed disk controller 7 LPT1 8 Real-time Clock 9 EGA/VGA display adapter 12 Mouse (PS/2) Memory Address Device 13 Math Coprocessor -------------- --------------------- 14 Hard Disk controller A000-BFFF EGA Graphics Adapter A000-C7FF VGA Graphics Adapter B000-BFFF Mono Graphics Adapter B800-BFFF Color Graphics Adapter E000-FFFF AT BIOS 6. Technical Support ==================== 6.1. Contacting Cirrus Logic's Technical Support ------------------------------------------------ Cirrus Logic's CS89XX Technical Application Support can be reached at:: Telephone :(800) 888-5016 (from inside U.S. and Canada) :(512) 442-7555 (from outside the U.S. and Canada) Fax :(512) 912-3871 Email :ethernet@crystal.cirrus.com WWW :http://www.cirrus.com 6.2. Information Required before Contacting Technical Support ------------------------------------------------------------- Before contacting Cirrus Logic for technical support, be prepared to provide as Much of the following information as possible. 1.) Adapter type (CRD8900, CDB8900, CDB8920, etc.) 2.) Adapter configuration * IO Base, Memory Base, IO or memory mode enabled, IRQ, DMA channel * Plug and Play enabled/disabled (CS8920-based adapters only) * Configured for media auto-detect or specific media type (which type). 3.) PC System's Configuration * Plug and Play system (yes/no) * BIOS (make and version) * System make and model * CPU (type and speed) * System RAM * SCSI Adapter 4.) Software * CS89XX driver and version * Your network operating system and version * Your system's OS version * Version of all protocol support files 5.) Any Error Message displayed. 6.3 Obtaining the Latest Driver Version --------------------------------------- You can obtain the latest CS89XX drivers and support software from Cirrus Logic's Web site. You can also contact Cirrus Logic's Technical Support (email: ethernet@crystal.cirrus.com) and request that you be registered for automatic software-update notification. Cirrus Logic maintains a web page at http://www.cirrus.com with the latest drivers and technical publications. 6.4. Current maintainer ----------------------- In February 2000 the maintenance of this driver was assumed by Andrew Morton. 6.5 Kernel module parameters ---------------------------- For use in embedded environments with no cs89x0 EEPROM, the kernel boot parameter ``cs89x0_media=`` has been implemented. Usage is:: cs89x0_media=rj45 or cs89x0_media=aui or cs89x0_media=bnc |