Linux Audio

Check our new training course

Embedded Linux Audio

Check our new training course
with Creative Commons CC-BY-SA
lecture materials

Bootlin logo

Elixir Cross Referencer

Loading...
   1
   2
   3
   4
   5
   6
   7
   8
   9
  10
  11
  12
  13
  14
  15
  16
  17
  18
  19
  20
  21
  22
  23
  24
  25
  26
  27
  28
  29
  30
  31
  32
  33
  34
  35
  36
  37
  38
  39
  40
  41
  42
  43
  44
  45
  46
  47
  48
  49
  50
  51
  52
  53
  54
  55
  56
  57
  58
  59
  60
  61
  62
  63
  64
  65
  66
  67
  68
  69
  70
  71
  72
  73
  74
  75
  76
  77
  78
  79
  80
  81
  82
  83
  84
  85
  86
  87
  88
  89
  90
  91
  92
  93
  94
  95
  96
  97
  98
  99
 100
 101
 102
 103
 104
 105
 106
 107
 108
 109
 110
 111
 112
 113
 114
 115
 116
 117
 118
 119
 120
 121
 122
 123
 124
 125
 126
 127
 128
 129
 130
 131
 132
 133
 134
 135
 136
 137
 138
 139
 140
 141
 142
 143
 144
 145
 146
 147
 148
 149
 150
 151
 152
 153
 154
 155
 156
 157
 158
 159
 160
 161
 162
 163
 164
 165
 166
 167
 168
 169
 170
 171
 172
 173
 174
 175
 176
 177
 178
 179
 180
 181
 182
 183
 184
 185
 186
 187
 188
 189
 190
 191
 192
 193
 194
 195
 196
 197
 198
 199
 200
 201
 202
 203
 204
 205
 206
 207
 208
 209
 210
 211
 212
 213
 214
 215
 216
 217
 218
 219
 220
 221
 222
 223
 224
 225
 226
 227
 228
 229
 230
 231
 232
 233
 234
 235
 236
 237
 238
 239
 240
 241
 242
 243
 244
 245
 246
 247
 248
 249
 250
 251
 252
 253
 254
 255
 256
 257
 258
 259
 260
 261
 262
 263
 264
 265
 266
 267
 268
 269
 270
 271
 272
 273
 274
 275
 276
 277
 278
 279
 280
 281
 282
 283
 284
 285
 286
 287
 288
 289
 290
 291
 292
 293
 294
 295
 296
 297
 298
 299
 300
 301
 302
 303
 304
 305
 306
 307
 308
 309
 310
 311
 312
 313
 314
 315
 316
 317
 318
 319
 320
 321
 322
 323
 324
 325
 326
 327
 328
 329
 330
 331
 332
 333
 334
 335
 336
 337
 338
 339
 340
 341
 342
 343
 344
 345
 346
 347
 348
 349
 350
 351
 352
 353
 354
 355
 356
 357
 358
 359
 360
 361
 362
 363
 364
 365
 366
 367
 368
 369
 370
 371
 372
 373
 374
 375
 376
 377
 378
 379
 380
 381
 382
 383
 384
 385
 386
 387
 388
 389
 390
 391
 392
 393
 394
 395
 396
 397
 398
 399
 400
 401
 402
 403
 404
 405
 406
 407
 408
 409
 410
 411
 412
 413
 414
 415
 416
 417
 418
 419
 420
 421
 422
 423
 424
 425
 426
 427
 428
 429
 430
 431
 432
 433
 434
 435
 436
 437
 438
 439
 440
 441
 442
 443
 444
 445
 446
 447
 448
 449
 450
 451
 452
 453
 454
 455
 456
 457
 458
 459
 460
 461
 462
 463
 464
 465
 466
 467
 468
 469
 470
 471
 472
 473
 474
 475
 476
 477
 478
 479
 480
 481
 482
 483
 484
 485
 486
 487
 488
 489
 490
 491
 492
 493
 494
 495
 496
 497
 498
 499
 500
 501
 502
 503
 504
 505
 506
 507
 508
 509
 510
 511
 512
 513
 514
 515
 516
 517
 518
 519
 520
 521
 522
 523
 524
 525
 526
 527
 528
 529
 530
 531
 532
 533
 534
 535
 536
 537
 538
 539
 540
 541
 542
 543
 544
 545
 546
 547
 548
 549
 550
 551
 552
 553
 554
 555
 556
 557
 558
 559
 560
 561
 562
 563
 564
 565
 566
 567
 568
 569
 570
 571
 572
 573
 574
 575
 576
 577
 578
 579
 580
 581
 582
 583
 584
 585
 586
 587
 588
 589
 590
 591
 592
 593
 594
 595
 596
 597
 598
 599
 600
 601
 602
 603
 604
 605
 606
 607
 608
 609
 610
 611
 612
 613
 614
 615
 616
 617
 618
 619
 620
 621
 622
 623
 624
 625
 626
 627
 628
 629
 630
 631
 632
 633
 634
 635
 636
 637
 638
 639
 640
 641
 642
 643
 644
 645
 646
 647
 648
 649
 650
 651
 652
 653
 654
 655
 656
 657
 658
 659
 660
 661
 662
 663
 664
 665
 666
 667
 668
 669
 670
 671
 672
 673
 674
 675
 676
 677
 678
 679
 680
 681
 682
 683
 684
 685
 686
 687
 688
 689
 690
 691
 692
 693
 694
 695
 696
 697
 698
 699
 700
 701
 702
 703
 704
 705
 706
 707
 708
 709
 710
 711
 712
 713
 714
 715
 716
 717
 718
 719
 720
 721
 722
 723
 724
 725
 726
 727
 728
 729
 730
 731
 732
 733
 734
 735
 736
 737
 738
 739
 740
 741
 742
 743
 744
 745
 746
 747
 748
 749
 750
 751
 752
 753
 754
 755
 756
 757
 758
 759
 760
 761
 762
 763
 764
 765
 766
 767
 768
 769
 770
 771
 772
 773
 774
 775
 776
 777
 778
 779
 780
 781
 782
 783
 784
 785
 786
 787
 788
 789
 790
 791
 792
 793
 794
 795
 796
 797
 798
 799
 800
 801
 802
 803
 804
 805
 806
 807
 808
 809
 810
 811
 812
 813
 814
 815
 816
 817
 818
 819
 820
 821
 822
 823
 824
 825
 826
 827
 828
 829
 830
 831
 832
 833
 834
 835
 836
 837
 838
 839
 840
 841
 842
 843
 844
 845
 846
 847
 848
 849
 850
 851
 852
 853
 854
 855
 856
 857
 858
 859
 860
 861
 862
 863
 864
 865
 866
 867
 868
 869
 870
 871
 872
 873
 874
 875
 876
 877
 878
 879
 880
 881
 882
 883
 884
 885
 886
 887
 888
 889
 890
 891
 892
 893
 894
 895
 896
 897
 898
 899
 900
 901
 902
 903
 904
 905
 906
 907
 908
 909
 910
 911
 912
 913
 914
 915
 916
 917
 918
 919
 920
 921
 922
 923
 924
 925
 926
 927
 928
 929
 930
 931
 932
 933
 934
 935
 936
 937
 938
 939
 940
 941
 942
 943
 944
 945
 946
 947
 948
 949
 950
 951
 952
 953
 954
 955
 956
 957
 958
 959
 960
 961
 962
 963
 964
 965
 966
 967
 968
 969
 970
 971
 972
 973
 974
 975
 976
 977
 978
 979
 980
 981
 982
 983
 984
 985
 986
 987
 988
 989
 990
 991
 992
 993
 994
 995
 996
 997
 998
 999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
.. SPDX-License-Identifier: GPL-2.0 OR Linux-OpenIB
.. include:: <isonum.txt>

================
Ethtool counters
================

:Copyright: |copy| 2023, NVIDIA CORPORATION & AFFILIATES. All rights reserved.

Contents
========

- `Overview`_
- `Groups`_
- `Types`_
- `Descriptions`_

Overview
========

There are several counter groups based on where the counter is being counted. In
addition, each group of counters may have different counter types.

These counter groups are based on which component in a networking setup,
illustrated below, that they describe::

                                                  ----------------------------------------
                                                  |                                      |
    ----------------------------------------    ---------------------------------------- |
    |              Hypervisor              |    |                  VM                  | |
    |                                      |    |                                      | |
    | -------------------  --------------- |    | -------------------  --------------- | |
    | | Ethernet driver |  | RDMA driver | |    | | Ethernet driver |  | RDMA driver | | |
    | -------------------  --------------- |    | -------------------  --------------- | |
    |           |                 |        |    |           |                 |        | |
    |           -------------------        |    |           -------------------        | |
    |                   |                  |    |                   |                  |--
    ----------------------------------------    ----------------------------------------
                        |                                           |
            -------------               -----------------------------
            |                           |
         ------                      ------ ------ ------         ------      ------      ------
    -----| PF |----------------------| VF |-| VF |-| VF |-----  --| PF |--- --| PF |--- --| PF |---
    |    ------                      ------ ------ ------    |  | ------  | | ------  | | ------  |
    |                                                        |  |         | |         | |         |
    |                                                        |  |         | |         | |         |
    |                                                        |  |         | |         | |         |
    | eSwitch                                                |  | eSwitch | | eSwitch | | eSwitch |
    ----------------------------------------------------------  ----------- ----------- -----------
               -------------------------------------------------------------------------------
               |                                                                             |
               |                                                                             |
               | Uplink (no counters)                                                        |
               -------------------------------------------------------------------------------
                       ---------------------------------------------------------------
                       |                                                             |
                       |                                                             |
                       | MPFS (no counters)                                          |
                       ---------------------------------------------------------------
                                                     |
                                                     |
                                                     | Port

Groups
======

Ring
  Software counters populated by the driver stack.

Netdev
  An aggregation of software ring counters.

vPort counters
  Traffic counters and drops due to steering or no buffers. May indicate issues
  with NIC. These counters include Ethernet traffic counters (including Raw
  Ethernet) and RDMA/RoCE traffic counters.

Physical port counters
  Counters that collect statistics about the PFs and VFs. May indicate issues
  with NIC, link, or network. This measuring point holds information on
  standardized counters like IEEE 802.3, RFC2863, RFC 2819, RFC 3635 and
  additional counters like flow control, FEC and more. Physical port counters
  are not exposed to virtual machines.

Priority Port Counters
  A set of the physical port counters, per priority per port.

Types
=====

Counters are divided into three types.

Traffic Informative Counters
  Counters which count traffic. These counters can be used for load estimation
  or for general debug.

Traffic Acceleration Counters
  Counters which count traffic that was accelerated by Mellanox driver or by
  hardware. The counters are an additional layer to the informative counter set,
  and the same traffic is counted in both informative and acceleration counters.

.. [#accel] Traffic acceleration counter.

Error Counters
  Increment of these counters might indicate a problem. Each of these counters
  has an explanation and correction action.

Statistic can be fetched via the `ip link` or `ethtool` commands. `ethtool`
provides more detailed information.::

    ip –s link show <if-name>
    ethtool -S <if-name>

Descriptions
============

XSK, PTP, and QoS counters that are similar to counters defined previously will
not be separately listed. For example, `ptp_tx[i]_packets` will not be
explicitly documented since `tx[i]_packets` describes the behavior of both
counters, except `ptp_tx[i]_packets` is only counted when precision time
protocol is used.

Ring / Netdev Counter
----------------------------
The following counters are available per ring or software port.

These counters provide information on the amount of traffic that was accelerated
by the NIC. The counters are counting the accelerated traffic in addition to the
standard counters which counts it (i.e. accelerated traffic is counted twice).

The counter names in the table below refers to both ring and port counters. The
notation for ring counters includes the [i] index without the braces. The
notation for port counters doesn't include the [i]. A counter name
`rx[i]_packets` will be printed as `rx0_packets` for ring 0 and `rx_packets` for
the software port.

.. flat-table:: Ring / Software Port Counter Table
   :widths: 2 3 1

   * - Counter
     - Description
     - Type

   * - `rx[i]_packets`
     - The number of packets received on ring i.
     - Informative

   * - `rx[i]_bytes`
     - The number of bytes received on ring i.
     - Informative

   * - `tx[i]_packets`
     - The number of packets transmitted on ring i.
     - Informative

   * - `tx[i]_bytes`
     - The number of bytes transmitted on ring i.
     - Informative

   * - `tx[i]_recover`
     - The number of times the SQ was recovered.
     - Error

   * - `tx[i]_cqes`
     - Number of CQEs events on SQ issued on ring i.
     - Informative

   * - `tx[i]_cqe_err`
     - The number of error CQEs encountered on the SQ for ring i.
     - Error

   * - `tx[i]_tso_packets`
     - The number of TSO packets transmitted on ring i [#accel]_.
     - Acceleration

   * - `tx[i]_tso_bytes`
     - The number of TSO bytes transmitted on ring i [#accel]_.
     - Acceleration

   * - `tx[i]_tso_inner_packets`
     - The number of TSO packets which are indicated to be carry internal
       encapsulation transmitted on ring i [#accel]_.
     - Acceleration

   * - `tx[i]_tso_inner_bytes`
     - The number of TSO bytes which are indicated to be carry internal
       encapsulation transmitted on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_gro_packets`
     - Number of received packets processed using hardware-accelerated GRO. The
       number of hardware GRO offloaded packets received on ring i.
     - Acceleration

   * - `rx[i]_gro_bytes`
     - Number of received bytes processed using hardware-accelerated GRO. The
       number of hardware GRO offloaded bytes received on ring i.
     - Acceleration

   * - `rx[i]_gro_skbs`
     - The number of receive SKBs constructed while performing
       hardware-accelerated GRO.
     - Informative

   * - `rx[i]_gro_match_packets`
     - Number of received packets processed using hardware-accelerated GRO that
       met the flow table match criteria.
     - Informative

   * - `rx[i]_gro_large_hds`
     - Number of receive packets using hardware-accelerated GRO that have large
       headers that require additional memory to be allocated.
     - Informative

   * - `rx[i]_lro_packets`
     - The number of LRO packets received on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_lro_bytes`
     - The number of LRO bytes received on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_ecn_mark`
     - The number of received packets where the ECN mark was turned on.
     - Informative

   * - `rx_oversize_pkts_buffer`
     - The number of dropped received packets due to length which arrived to RQ
       and exceed software buffer size allocated by the device for incoming
       traffic. It might imply that the device MTU is larger than the software
       buffers size.
     - Error

   * - `rx_oversize_pkts_sw_drop`
     - Number of received packets dropped in software because the CQE data is
       larger than the MTU size.
     - Error

   * - `rx[i]_csum_unnecessary`
     - Packets received with a `CHECKSUM_UNNECESSARY` on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_csum_unnecessary_inner`
     - Packets received with inner encapsulation with a `CHECKSUM_UNNECESSARY`
       on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_csum_none`
     - Packets received with a `CHECKSUM_NONE` on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_csum_complete`
     - Packets received with a `CHECKSUM_COMPLETE` on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_csum_complete_tail`
     - Number of received packets that had checksum calculation computed,
       potentially needed padding, and were able to do so with
       `CHECKSUM_PARTIAL`.
     - Informative

   * - `rx[i]_csum_complete_tail_slow`
     - Number of received packets that need padding larger than eight bytes for
       the checksum.
     - Informative

   * - `tx[i]_csum_partial`
     - Packets transmitted with a `CHECKSUM_PARTIAL` on ring i [#accel]_.
     - Acceleration

   * - `tx[i]_csum_partial_inner`
     - Packets transmitted with inner encapsulation with a `CHECKSUM_PARTIAL` on
       ring i [#accel]_.
     - Acceleration

   * - `tx[i]_csum_none`
     - Packets transmitted with no hardware checksum acceleration on ring i.
     - Informative

   * - `tx[i]_stopped` / `tx_queue_stopped` [#ring_global]_
     - Events where SQ was full on ring i. If this counter is increased, check
       the amount of buffers allocated for transmission.
     - Informative

   * - `tx[i]_wake` / `tx_queue_wake` [#ring_global]_
     - Events where SQ was full and has become not full on ring i.
     - Informative

   * - `tx[i]_dropped` / `tx_queue_dropped` [#ring_global]_
     - Packets transmitted that were dropped due to DMA mapping failure on
       ring i. If this counter is increased, check the amount of buffers
       allocated for transmission.
     - Error

   * - `tx[i]_nop`
     - The number of nop WQEs (empty WQEs) inserted to the SQ (related to
       ring i) due to the reach of the end of the cyclic buffer. When reaching
       near to the end of cyclic buffer the driver may add those empty WQEs to
       avoid handling a state the a WQE start in the end of the queue and ends
       in the beginning of the queue. This is a normal condition.
     - Informative

   * - `tx[i]_added_vlan_packets`
     - The number of packets sent where vlan tag insertion was offloaded to the
       hardware.
     - Acceleration

   * - `rx[i]_removed_vlan_packets`
     - The number of packets received where vlan tag stripping was offloaded to
       the hardware.
     - Acceleration

   * - `rx[i]_wqe_err`
     - The number of wrong opcodes received on ring i.
     - Error

   * - `rx[i]_mpwqe_frag`
     - The number of WQEs that failed to allocate compound page and hence
       fragmented MPWQE’s (Multi Packet WQEs) were used on ring i. If this
       counter raise, it may suggest that there is no enough memory for large
       pages, the driver allocated fragmented pages. This is not abnormal
       condition.
     - Informative

   * - `rx[i]_mpwqe_filler_cqes`
     - The number of filler CQEs events that were issued on ring i.
     - Informative

   * - `rx[i]_mpwqe_filler_strides`
     - The number of strides consumed by filler CQEs on ring i.
     - Informative

   * - `tx[i]_mpwqe_blks`
     - The number of send blocks processed from Multi-Packet WQEs (mpwqe).
     - Informative

   * - `tx[i]_mpwqe_pkts`
     - The number of send packets processed from Multi-Packet WQEs (mpwqe).
     - Informative

   * - `rx[i]_cqe_compress_blks`
     - The number of receive blocks with CQE compression on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_cqe_compress_pkts`
     - The number of receive packets with CQE compression on ring i [#accel]_.
     - Acceleration

   * - `rx[i]_arfs_err`
     - Number of flow rules that failed to be added to the flow table.
     - Error

   * - `rx[i]_recover`
     - The number of times the RQ was recovered.
     - Error

   * - `tx[i]_xmit_more`
     - The number of packets sent with `xmit_more` indication set on the skbuff
       (no doorbell).
     - Acceleration

   * - `ch[i]_poll`
     - The number of invocations of NAPI poll of channel i.
     - Informative

   * - `ch[i]_arm`
     - The number of times the NAPI poll function completed and armed the
       completion queues on channel i.
     - Informative

   * - `ch[i]_aff_change`
     - The number of times the NAPI poll function explicitly stopped execution
       on a CPU due to a change in affinity, on channel i.
     - Informative

   * - `ch[i]_events`
     - The number of hard interrupt events on the completion queues of channel i.
     - Informative

   * - `ch[i]_eq_rearm`
     - The number of times the EQ was recovered.
     - Error

   * - `ch[i]_force_irq`
     - Number of times NAPI is triggered by XSK wakeups by posting a NOP to
       ICOSQ.
     - Acceleration

   * - `rx[i]_congst_umr`
     - The number of times an outstanding UMR request is delayed due to
       congestion, on ring i.
     - Informative

   * - `rx_pp_alloc_fast`
     - Number of successful fast path allocations.
     - Informative

   * - `rx_pp_alloc_slow`
     - Number of slow path order-0 allocations.
     - Informative

   * - `rx_pp_alloc_slow_high_order`
     - Number of slow path high order allocations.
     - Informative

   * - `rx_pp_alloc_empty`
     - Counter is incremented when ptr ring is empty, so a slow path allocation
       was forced.
     - Informative

   * - `rx_pp_alloc_refill`
     - Counter is incremented when an allocation which triggered a refill of the
       cache.
     - Informative

   * - `rx_pp_alloc_waive`
     - Counter is incremented when pages obtained from the ptr ring that cannot
       be added to the cache due to a NUMA mismatch.
     - Informative

   * - `rx_pp_recycle_cached`
     - Counter is incremented when recycling placed page in the page pool cache.
     - Informative

   * - `rx_pp_recycle_cache_full`
     - Counter is incremented when page pool cache was full.
     - Informative

   * - `rx_pp_recycle_ring`
     - Counter is incremented when page placed into the ptr ring.
     - Informative

   * - `rx_pp_recycle_ring_full`
     - Counter is incremented when page released from page pool because the ptr
       ring was full.
     - Informative

   * - `rx_pp_recycle_released_ref`
     - Counter is incremented when page released (and not recycled) because
       refcnt > 1.
     - Informative

   * - `rx[i]_xsk_buff_alloc_err`
     - The number of times allocating an skb or XSK buffer failed in the XSK RQ
       context.
     - Error

   * - `rx[i]_xsk_arfs_err`
     - aRFS (accelerated Receive Flow Steering) does not occur in the XSK RQ
       context, so this counter should never increment.
     - Error

   * - `rx[i]_xdp_tx_xmit`
     - The number of packets forwarded back to the port due to XDP program
       `XDP_TX` action (bouncing). these packets are not counted by other
       software counters. These packets are counted by physical port and vPort
       counters.
     - Informative

   * - `rx[i]_xdp_tx_mpwqe`
     - Number of multi-packet WQEs transmitted by the netdev and `XDP_TX`-ed by
       the netdev during the RQ context.
     - Acceleration

   * - `rx[i]_xdp_tx_inlnw`
     - Number of WQE data segments transmitted where the data could be inlined
       in the WQE and then `XDP_TX`-ed during the RQ context.
     - Acceleration

   * - `rx[i]_xdp_tx_nops`
     - Number of NOP WQEBBs (WQE building blocks) received posted to the XDP SQ.
     - Acceleration

   * - `rx[i]_xdp_tx_full`
     - The number of packets that should have been forwarded back to the port
       due to `XDP_TX` action but were dropped due to full tx queue. These packets
       are not counted by other software counters. These packets are counted by
       physical port and vPort counters. You may open more rx queues and spread
       traffic rx over all queues and/or increase rx ring size.
     - Error

   * - `rx[i]_xdp_tx_err`
     - The number of times an `XDP_TX` error such as frame too long and frame
       too short occurred on `XDP_TX` ring of RX ring.
     - Error

   * - `rx[i]_xdp_tx_cqes` / `rx_xdp_tx_cqe` [#ring_global]_
     - The number of completions received on the CQ of the `XDP_TX` ring.
     - Informative

   * - `rx[i]_xdp_drop`
     - The number of packets dropped due to XDP program `XDP_DROP` action. these
       packets are not counted by other software counters. These packets are
       counted by physical port and vPort counters.
     - Informative

   * - `rx[i]_xdp_redirect`
     - The number of times an XDP redirect action was triggered on ring i.
     - Acceleration

   * - `tx[i]_xdp_xmit`
     - The number of packets redirected to the interface(due to XDP redirect).
       These packets are not counted by other software counters. These packets
       are counted by physical port and vPort counters.
     - Informative

   * - `tx[i]_xdp_full`
     - The number of packets redirected to the interface(due to XDP redirect),
       but were dropped due to full tx queue. these packets are not counted by
       other software counters. you may enlarge tx queues.
     - Informative

   * - `tx[i]_xdp_mpwqe`
     - Number of multi-packet WQEs offloaded onto the NIC that were
       `XDP_REDIRECT`-ed from other netdevs.
     - Acceleration

   * - `tx[i]_xdp_inlnw`
     - Number of WQE data segments where the data could be inlined in the WQE
       where the data segments were `XDP_REDIRECT`-ed from other netdevs.
     - Acceleration

   * - `tx[i]_xdp_nops`
     - Number of NOP WQEBBs (WQE building blocks) posted to the SQ that were
       `XDP_REDIRECT`-ed from other netdevs.
     - Acceleration

   * - `tx[i]_xdp_err`
     - The number of packets redirected to the interface(due to XDP redirect)
       but were dropped due to error such as frame too long and frame too short.
     - Error

   * - `tx[i]_xdp_cqes`
     - The number of completions received for packets redirected to the
       interface(due to XDP redirect) on the CQ.
     - Informative

   * - `tx[i]_xsk_xmit`
     - The number of packets transmitted using XSK zerocopy functionality.
     - Acceleration

   * - `tx[i]_xsk_mpwqe`
     - Number of multi-packet WQEs offloaded onto the NIC that were
       `XDP_REDIRECT`-ed from other netdevs.
     - Acceleration

   * - `tx[i]_xsk_inlnw`
     - Number of WQE data segments where the data could be inlined in the WQE
       that are transmitted using XSK zerocopy.
     - Acceleration

   * - `tx[i]_xsk_full`
     - Number of times doorbell is rung in XSK zerocopy mode when SQ is full.
     - Error

   * - `tx[i]_xsk_err`
     - Number of errors that occurred in XSK zerocopy mode such as if the data
       size is larger than the MTU size.
     - Error

   * - `tx[i]_xsk_cqes`
     - Number of CQEs processed in XSK zerocopy mode.
     - Acceleration

   * - `tx_tls_ctx`
     - Number of TLS TX HW offload contexts added to device for encryption.
     - Acceleration

   * - `tx_tls_del`
     - Number of TLS TX HW offload contexts removed from device (connection
       closed).
     - Acceleration

   * - `tx_tls_pool_alloc`
     - Number of times a unit of work is successfully allocated in the TLS HW
       offload pool.
     - Acceleration

   * - `tx_tls_pool_free`
     - Number of times a unit of work is freed in the TLS HW offload pool.
     - Acceleration

   * - `rx_tls_ctx`
     - Number of TLS RX HW offload contexts added to device for decryption.
     - Acceleration

   * - `rx_tls_del`
     - Number of TLS RX HW offload contexts deleted from device (connection has
       finished).
     - Acceleration

   * - `rx[i]_tls_decrypted_packets`
     - Number of successfully decrypted RX packets which were part of a TLS
       stream.
     - Acceleration

   * - `rx[i]_tls_decrypted_bytes`
     - Number of TLS payload bytes in RX packets which were successfully
       decrypted.
     - Acceleration

   * - `rx[i]_tls_resync_req_pkt`
     - Number of received TLS packets with a resync request.
     - Acceleration

   * - `rx[i]_tls_resync_req_start`
     - Number of times the TLS async resync request was started.
     - Acceleration

   * - `rx[i]_tls_resync_req_end`
     - Number of times the TLS async resync request properly ended with
       providing the HW tracked tcp-seq.
     - Acceleration

   * - `rx[i]_tls_resync_req_skip`
     - Number of times the TLS async resync request procedure was started but
       not properly ended.
     - Error

   * - `rx[i]_tls_resync_res_ok`
     - Number of times the TLS resync response call to the driver was
       successfully handled.
     - Acceleration

   * - `rx[i]_tls_resync_res_retry`
     - Number of times the TLS resync response call to the driver was
       reattempted when ICOSQ is full.
     - Error

   * - `rx[i]_tls_resync_res_skip`
     - Number of times the TLS resync response call to the driver was terminated
       unsuccessfully.
     - Error

   * - `rx[i]_tls_err`
     - Number of times when CQE TLS offload was problematic.
     - Error

   * - `tx[i]_tls_encrypted_packets`
     - The number of send packets that are TLS encrypted by the kernel.
     - Acceleration

   * - `tx[i]_tls_encrypted_bytes`
     - The number of send bytes that are TLS encrypted by the kernel.
     - Acceleration

   * - `tx[i]_tls_ooo`
     - Number of times out of order TLS SQE fragments were handled on ring i.
     - Acceleration

   * - `tx[i]_tls_dump_packets`
     - Number of TLS decrypted packets copied over from NIC over DMA.
     - Acceleration

   * - `tx[i]_tls_dump_bytes`
     - Number of TLS decrypted bytes copied over from NIC over DMA.
     - Acceleration

   * - `tx[i]_tls_resync_bytes`
     - Number of TLS bytes requested to be resynchronized in order to be
       decrypted.
     - Acceleration

   * - `tx[i]_tls_skip_no_sync_data`
     - Number of TLS send data that can safely be skipped / do not need to be
       decrypted.
     - Acceleration

   * - `tx[i]_tls_drop_no_sync_data`
     - Number of TLS send data that were dropped due to retransmission of TLS
       data.
     - Acceleration

   * - `ptp_cq[i]_abort`
     - Number of times a CQE has to be skipped in precision time protocol due to
       a skew between the port timestamp and CQE timestamp being greater than
       128 seconds.
     - Error

   * - `ptp_cq[i]_abort_abs_diff_ns`
     - Accumulation of time differences between the port timestamp and CQE
       timestamp when the difference is greater than 128 seconds in precision
       time protocol.
     - Error

.. [#ring_global] The corresponding ring and global counters do not share the
                  same name (i.e. do not follow the common naming scheme).

vPort Counters
--------------
Counters on the NIC port that is connected to a eSwitch.

.. flat-table:: vPort Counter Table
   :widths: 2 3 1

   * - Counter
     - Description
     - Type

   * - `rx_vport_unicast_packets`
     - Unicast packets received, steered to a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `rx_vport_unicast_bytes`
     - Unicast bytes received, steered to a port including Raw Ethernet QP/DPDK
       traffic, excluding RDMA traffic.
     - Informative

   * - `tx_vport_unicast_packets`
     - Unicast packets transmitted, steered from a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `tx_vport_unicast_bytes`
     - Unicast bytes transmitted, steered from a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `rx_vport_multicast_packets`
     - Multicast packets received, steered to a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `rx_vport_multicast_bytes`
     - Multicast bytes received, steered to a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `tx_vport_multicast_packets`
     - Multicast packets transmitted, steered from a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `tx_vport_multicast_bytes`
     - Multicast bytes transmitted, steered from a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `rx_vport_broadcast_packets`
     - Broadcast packets received, steered to a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `rx_vport_broadcast_bytes`
     - Broadcast bytes received, steered to a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `tx_vport_broadcast_packets`
     - Broadcast packets transmitted, steered from a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `tx_vport_broadcast_bytes`
     - Broadcast bytes transmitted, steered from a port including Raw Ethernet
       QP/DPDK traffic, excluding RDMA traffic.
     - Informative

   * - `rx_vport_rdma_unicast_packets`
     - RDMA unicast packets received, steered to a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `rx_vport_rdma_unicast_bytes`
     - RDMA unicast bytes received, steered to a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `tx_vport_rdma_unicast_packets`
     - RDMA unicast packets transmitted, steered from a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `tx_vport_rdma_unicast_bytes`
     - RDMA unicast bytes transmitted, steered from a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `rx_vport_rdma_multicast_packets`
     - RDMA multicast packets received, steered to a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `rx_vport_rdma_multicast_bytes`
     - RDMA multicast bytes received, steered to a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `tx_vport_rdma_multicast_packets`
     - RDMA multicast packets transmitted, steered from a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `tx_vport_rdma_multicast_bytes`
     - RDMA multicast bytes transmitted, steered from a port (counters counts
       RoCE/UD/RC traffic) [#accel]_.
     - Acceleration

   * - `rx_steer_missed_packets`
     - Number of packets that was received by the NIC, however was discarded
       because it did not match any flow in the NIC flow table.
     - Error

   * - `rx_packets`
     - Representor only: packets received, that were handled by the hypervisor.
     - Informative

   * - `rx_bytes`
     - Representor only: bytes received, that were handled by the hypervisor.
     - Informative

   * - `tx_packets`
     - Representor only: packets transmitted, that were handled by the
       hypervisor.
     - Informative

   * - `tx_bytes`
     - Representor only: bytes transmitted, that were handled by the hypervisor.
     - Informative

   * - `dev_internal_queue_oob`
     - The number of dropped packets due to lack of receive WQEs for an internal
       device RQ.
     - Error

Physical Port Counters
----------------------
The physical port counters are the counters on the external port connecting the
adapter to the network. This measuring point holds information on standardized
counters like IEEE 802.3, RFC2863, RFC 2819, RFC 3635 and additional counters
like flow control, FEC and more.

.. flat-table:: Physical Port Counter Table
   :widths: 2 3 1

   * - Counter
     - Description
     - Type

   * - `rx_packets_phy`
     - The number of packets received on the physical port. This counter doesn’t
       include packets that were discarded due to FCS, frame size and similar
       errors.
     - Informative

   * - `tx_packets_phy`
     - The number of packets transmitted on the physical port.
     - Informative

   * - `rx_bytes_phy`
     - The number of bytes received on the physical port, including Ethernet
       header and FCS.
     - Informative

   * - `tx_bytes_phy`
     - The number of bytes transmitted on the physical port.
     - Informative

   * - `rx_multicast_phy`
     - The number of multicast packets received on the physical port.
     - Informative

   * - `tx_multicast_phy`
     - The number of multicast packets transmitted on the physical port.
     - Informative

   * - `rx_broadcast_phy`
     - The number of broadcast packets received on the physical port.
     - Informative

   * - `tx_broadcast_phy`
     - The number of broadcast packets transmitted on the physical port.
     - Informative

   * - `rx_crc_errors_phy`
     - The number of dropped received packets due to FCS (Frame Check Sequence)
       error on the physical port. If this counter is increased in high rate,
       check the link quality using `rx_symbol_error_phy` and
       `rx_corrected_bits_phy` counters below.
     - Error

   * - `rx_in_range_len_errors_phy`
     - The number of received packets dropped due to length/type errors on a
       physical port.
     - Error

   * - `rx_out_of_range_len_phy`
     - The number of received packets dropped due to length greater than allowed
       on a physical port. If this counter is increasing, it implies that the
       peer connected to the adapter has a larger MTU configured. Using same MTU
       configuration shall resolve this issue.
     - Error

   * - `rx_oversize_pkts_phy`
     - The number of dropped received packets due to length which exceed MTU
       size on a physical port. If this counter is increasing, it implies that
       the peer connected to the adapter has a larger MTU configured. Using same
       MTU configuration shall resolve this issue.
     - Error

   * - `rx_symbol_err_phy`
     - The number of received packets dropped due to physical coding errors
       (symbol errors) on a physical port.
     - Error

   * - `rx_mac_control_phy`
     - The number of MAC control packets received on the physical port.
     - Informative

   * - `tx_mac_control_phy`
     - The number of MAC control packets transmitted on the physical port.
     - Informative

   * - `rx_pause_ctrl_phy`
     - The number of link layer pause packets received on a physical port. If
       this counter is increasing, it implies that the network is congested and
       cannot absorb the traffic coming from to the adapter.
     - Informative

   * - `tx_pause_ctrl_phy`
     - The number of link layer pause packets transmitted on a physical port. If
       this counter is increasing, it implies that the NIC is congested and
       cannot absorb the traffic coming from the network.
     - Informative

   * - `rx_unsupported_op_phy`
     - The number of MAC control packets received with unsupported opcode on a
       physical port.
     - Error

   * - `rx_discards_phy`
     - The number of received packets dropped due to lack of buffers on a
       physical port. If this counter is increasing, it implies that the adapter
       is congested and cannot absorb the traffic coming from the network.
     - Error

   * - `tx_discards_phy`
     - The number of packets which were discarded on transmission, even no
       errors were detected. the drop might occur due to link in down state,
       head of line drop, pause from the network, etc.
     - Error

   * - `tx_errors_phy`
     - The number of transmitted packets dropped due to a length which exceed
       MTU size on a physical port.
     - Error

   * - `rx_undersize_pkts_phy`
     - The number of received packets dropped due to length which is shorter
       than 64 bytes on a physical port. If this counter is increasing, it
       implies that the peer connected to the adapter has a non-standard MTU
       configured or malformed packet had arrived.
     - Error

   * - `rx_fragments_phy`
     - The number of received packets dropped due to a length which is shorter
       than 64 bytes and has FCS error on a physical port. If this counter is
       increasing, it implies that the peer connected to the adapter has a
       non-standard MTU configured.
     - Error

   * - `rx_jabbers_phy`
     - The number of received packets d due to a length which is longer than 64
       bytes and had FCS error on a physical port.
     - Error

   * - `rx_64_bytes_phy`
     - The number of packets received on the physical port with size of 64 bytes.
     - Informative

   * - `rx_65_to_127_bytes_phy`
     - The number of packets received on the physical port with size of 65 to
       127 bytes.
     - Informative

   * - `rx_128_to_255_bytes_phy`
     - The number of packets received on the physical port with size of 128 to
       255 bytes.
     - Informative

   * - `rx_256_to_511_bytes_phy`
     - The number of packets received on the physical port with size of 256 to
       512 bytes.
     - Informative

   * - `rx_512_to_1023_bytes_phy`
     - The number of packets received on the physical port with size of 512 to
       1023 bytes.
     - Informative

   * - `rx_1024_to_1518_bytes_phy`
     - The number of packets received on the physical port with size of 1024 to
       1518 bytes.
     - Informative

   * - `rx_1519_to_2047_bytes_phy`
     - The number of packets received on the physical port with size of 1519 to
       2047 bytes.
     - Informative

   * - `rx_2048_to_4095_bytes_phy`
     - The number of packets received on the physical port with size of 2048 to
       4095 bytes.
     - Informative

   * - `rx_4096_to_8191_bytes_phy`
     - The number of packets received on the physical port with size of 4096 to
       8191 bytes.
     - Informative

   * - `rx_8192_to_10239_bytes_phy`
     - The number of packets received on the physical port with size of 8192 to
       10239 bytes.
     - Informative

   * - `link_down_events_phy`
     - The number of times where the link operative state changed to down. In
       case this counter is increasing it may imply on port flapping. You may
       need to replace the cable/transceiver.
     - Error

   * - `rx_out_of_buffer`
     - Number of times receive queue had no software buffers allocated for the
       adapter's incoming traffic.
     - Error

   * - `module_bus_stuck`
     - The number of times that module's I\ :sup:`2`\C bus (data or clock)
       short-wire was detected. You may need to replace the cable/transceiver.
     - Error

   * - `module_high_temp`
     - The number of times that the module temperature was too high. If this
       issue persist, you may need to check the ambient temperature or replace
       the cable/transceiver module.
     - Error

   * - `module_bad_shorted`
     - The number of times that the module cables were shorted. You may need to
       replace the cable/transceiver module.
     - Error

   * - `module_unplug`
     - The number of times that module was ejected.
     - Informative

   * - `rx_buffer_passed_thres_phy`
     - The number of events where the port receive buffer was over 85% full.
     - Informative

   * - `tx_pause_storm_warning_events`
     - The number of times the device was sending pauses for a long period of
       time.
     - Informative

   * - `tx_pause_storm_error_events`
     - The number of times the device was sending pauses for a long period of
       time, reaching time out and disabling transmission of pause frames. on
       the period where pause frames were disabled, drop could have been
       occurred.
     - Error

   * - `rx[i]_buff_alloc_err`
     - Failed to allocate a buffer to received packet (or SKB) on ring i.
     - Error

   * - `rx_bits_phy`
     - This counter provides information on the total amount of traffic that
       could have been received and can be used as a guideline to measure the
       ratio of errored traffic in `rx_pcs_symbol_err_phy` and
       `rx_corrected_bits_phy`.
     - Informative

   * - `rx_pcs_symbol_err_phy`
     - This counter counts the number of symbol errors that wasn’t corrected by
       FEC correction algorithm or that FEC algorithm was not active on this
       interface. If this counter is increasing, it implies that the link
       between the NIC and the network is suffering from high BER, and that
       traffic is lost. You may need to replace the cable/transceiver. The error
       rate is the number of `rx_pcs_symbol_err_phy` divided by the number of
       `rx_bits_phy` on a specific time frame.
     - Error

   * - `rx_corrected_bits_phy`
     - The number of corrected bits on this port according to active FEC
       (RS/FC). If this counter is increasing, it implies that the link between
       the NIC and the network is suffering from high BER. The corrected bit
       rate is the number of `rx_corrected_bits_phy` divided by the number of
       `rx_bits_phy` on a specific time frame.
     - Error

   * - `rx_err_lane_[l]_phy`
     - This counter counts the number of physical raw errors per lane l index.
       The counter counts errors before FEC corrections. If this counter is
       increasing, it implies that the link between the NIC and the network is
       suffering from high BER, and that traffic might be lost. You may need to
       replace the cable/transceiver. Please check in accordance with
       `rx_corrected_bits_phy`.
     - Error

   * - `rx_global_pause`
     - The number of pause packets received on the physical port. If this
       counter is increasing, it implies that the network is congested and
       cannot absorb the traffic coming from the adapter. Note: This counter is
       only enabled when global pause mode is enabled.
     - Informative

   * - `rx_global_pause_duration`
     - The duration of pause received (in microSec) on the physical port. The
       counter represents the time the port did not send any traffic. If this
       counter is increasing, it implies that the network is congested and
       cannot absorb the traffic coming from the adapter. Note: This counter is
       only enabled when global pause mode is enabled.
     - Informative

   * - `tx_global_pause`
     - The number of pause packets transmitted on a physical port. If this
       counter is increasing, it implies that the adapter is congested and
       cannot absorb the traffic coming from the network. Note: This counter is
       only enabled when global pause mode is enabled.
     - Informative

   * - `tx_global_pause_duration`
     - The duration of pause transmitter (in microSec) on the physical port.
       Note: This counter is only enabled when global pause mode is enabled.
     - Informative

   * - `rx_global_pause_transition`
     - The number of times a transition from Xoff to Xon on the physical port
       has occurred. Note: This counter is only enabled when global pause mode
       is enabled.
     - Informative

   * - `rx_if_down_packets`
     - The number of received packets that were dropped due to interface down.
     - Informative

Priority Port Counters
----------------------
The following counters are physical port counters that are counted per L2
priority (0-7).

**Note:** `p` in the counter name represents the priority.

.. flat-table:: Priority Port Counter Table
   :widths: 2 3 1

   * - Counter
     - Description
     - Type

   * - `rx_prio[p]_bytes`
     - The number of bytes received with priority p on the physical port.
     - Informative

   * - `rx_prio[p]_packets`
     - The number of packets received with priority p on the physical port.
     - Informative

   * - `tx_prio[p]_bytes`
     - The number of bytes transmitted on priority p on the physical port.
     - Informative

   * - `tx_prio[p]_packets`
     - The number of packets transmitted on priority p on the physical port.
     - Informative

   * - `rx_prio[p]_pause`
     - The number of pause packets received with priority p on a physical port.
       If this counter is increasing, it implies that the network is congested
       and cannot absorb the traffic coming from the adapter. Note: This counter
       is available only if PFC was enabled on priority p.
     - Informative

   * - `rx_prio[p]_pause_duration`
     - The duration of pause received (in microSec) on priority p on the
       physical port. The counter represents the time the port did not send any
       traffic on this priority. If this counter is increasing, it implies that
       the network is congested and cannot absorb the traffic coming from the
       adapter. Note: This counter is available only if PFC was enabled on
       priority p.
     - Informative

   * - `rx_prio[p]_pause_transition`
     - The number of times a transition from Xoff to Xon on priority p on the
       physical port has occurred. Note: This counter is available only if PFC
       was enabled on priority p.
     - Informative

   * - `tx_prio[p]_pause`
     - The number of pause packets transmitted on priority p on a physical port.
       If this counter is increasing, it implies that the adapter is congested
       and cannot absorb the traffic coming from the network. Note: This counter
       is available only if PFC was enabled on priority p.
     - Informative

   * - `tx_prio[p]_pause_duration`
     - The duration of pause transmitter (in microSec) on priority p on the
       physical port. Note: This counter is available only if PFC was enabled on
       priority p.
     - Informative

   * - `rx_prio[p]_buf_discard`
     - The number of packets discarded by device due to lack of per host receive
       buffers.
     - Informative

   * - `rx_prio[p]_cong_discard`
     - The number of packets discarded by device due to per host congestion.
     - Informative

   * - `rx_prio[p]_marked`
     - The number of packets ecn marked by device due to per host congestion.
     - Informative

   * - `rx_prio[p]_discards`
     - The number of packets discarded by device due to lack of receive buffers.
     - Informative

Device Counters
---------------
.. flat-table:: Device Counter Table
   :widths: 2 3 1

   * - Counter
     - Description
     - Type

   * - `rx_pci_signal_integrity`
     - Counts physical layer PCIe signal integrity errors, the number of
       transitions to recovery due to Framing errors and CRC (dlp and tlp). If
       this counter is raising, try moving the adapter card to a different slot
       to rule out a bad PCI slot. Validate that you are running with the latest
       firmware available and latest server BIOS version.
     - Error

   * - `tx_pci_signal_integrity`
     - Counts physical layer PCIe signal integrity errors, the number of
       transition to recovery initiated by the other side (moving to recovery
       due to getting TS/EIEOS). If this counter is raising, try moving the
       adapter card to a different slot to rule out a bad PCI slot. Validate
       that you are running with the latest firmware available and latest server
       BIOS version.
     - Error

   * - `outbound_pci_buffer_overflow`
     - The number of packets dropped due to pci buffer overflow. If this counter
       is raising in high rate, it might indicate that the receive traffic rate
       for a host is larger than the PCIe bus and therefore a congestion occurs.
     - Informative

   * - `outbound_pci_stalled_rd`
     - The percentage (in the range 0...100) of time within the last second that
       the NIC had outbound non-posted reads requests but could not perform the
       operation due to insufficient posted credits.
     - Informative

   * - `outbound_pci_stalled_wr`
     - The percentage (in the range 0...100) of time within the last second that
       the NIC had outbound posted writes requests but could not perform the
       operation due to insufficient posted credits.
     - Informative

   * - `outbound_pci_stalled_rd_events`
     - The number of seconds where `outbound_pci_stalled_rd` was above 30%.
     - Informative

   * - `outbound_pci_stalled_wr_events`
     - The number of seconds where `outbound_pci_stalled_wr` was above 30%.
     - Informative

   * - `dev_out_of_buffer`
     - The number of times the device owned queue had not enough buffers
       allocated.
     - Error